What are the process requirements for making welded air ducts? Both ends of the expansion joint are welded to the outer wall of the air duct. high quality Air compression hose When the fan coil unit is equipped with two air outlets, the double-layer shutter with regulating valve should be selected. Usually only small installation space is required. Without increasing any pressure drop, a circular pipe with a diameter of 200mm in the same installation space can replace 250 × 150mm rectangular pipe. Features: The iron sheet is prone to chemical reaction in various environments, causing corrosion and rust. However, zinc hardly changes in dry air. The thermal insulation and fire resistance performance indicators of the welded air duct system shall meet the requirements of Code for Acceptance of Construction Quality of Ventilation and Air Conditioning Engineering (GB50243) and Technical Specification for Ventilation Ducts (JGJ141) respectively. In the ventilation system: supply fresh air and exhaust gas, exhaust harmful gas outdoors, and send outdoor fresh air indoors. This technology is widely used in cleaning projects such as various process pipelines, oil and gas pipelines in oil fields, especially for pipeline cleaning of long-distance fluid transportation, which has advantages that cannot be replaced by other technologies. When the air leakage rate exceeds the requirements of the design and acceptance specifications, the leakage can be detected by listening, touching, observing, water or smoke, and the air leakage position can be found and marked; After repair, retest until qualified. Safety seal ring leak proof system. The exquisite spiral pressing rib technology enables the spiral air duct to have good strength under pressure, Air compression hose Where can I find it? With the addition of spiral ribs, the thickness of the seam is four times that of the pipe body. The rigidity of the pipe is very large, which shows the advantages of firmness. It can withstand large pressure loads without damaging deformation. The thickness of materials can be reduced by 15%, reducing costs.
Xiamen Air compression hose Prevention of vibration and noise during installation: the prevention of vibration and noise during installation is a key point in the installation process. The prevention of vibration and noise of spiral air duct during installation is mainly from the following aspects: 1. The fan and spiral air duct are connected by hose, and the hose at the suction inlet of the fan shall be installed with appropriate tightness, Avoid noise and vibration caused by reducing the area of air inlet and outlet due to loose soft connection. 2. The spiral air duct shall be made, installed and connected with the components. The connection shall be tight to reduce the gap and avoid air leakage noise. 3 In order to prevent the spiral air duct from vibration, fixed supports shall be installed at the turning of each system spiral air duct and at the connection with the ventilator and the air outlet for shock absorption. 4 The vibration damping device shall be set according to the design requirements or construction specifications during fan installation. Air leakage rate test of spiral air duct After the installation of spiral air duct, air leakage rate test shall be carried out. According to the specifications, the air leakage rate test of spiral air duct adopts the combination of light leakage legality and quantitative air leakage rate test. The light leakage method is suitable for the tightness test of medium and low pressure systems; The air leakage rate test is suitable for sampling inspection of medium pressure system and full detection of high pressure system. Light leak detection of spiral air duct Light leak detection is a qualitative method to detect the tightness of the spiral air duct of the system by using the strong penetration of light to holes. The test method is to use a bulb with protective cover whose voltage is not higher than 36V and power is more than 100W in the spiral air duct on a certain length of spiral air duct in dark environment, and slowly move from one end of the spiral air duct to the other end. If light can be observed outside the spiral air duct during the test, it indicates that there is a leak point in the spiral air duct, and repair the leak point of the spiral air duct. Air compression hose Where can I find it? The light leak detection method of the low-pressure system adopts the method of subsection detection and summary analysis. The spiral air duct of the tested system is not allowed to have multiple obvious light leaks in the form of slits. The spiral air duct of the low-pressure system has no more than two light leak points every 10 meters, and the average joint of 100 meters is no more than 16; For every 10 joints of spiral air duct of medium pressure system, no more than 1 light leak point, and no more than 8 joints per 100 meters are qualified.
Xiamen Air compression hose It is widely used in mining, chemical industry, construction and iron and steel fields. At present, 90% of ball mills, rod mills and moistening mills on the market still use manganese steel cylinder liners, and the manganese steel material consumed on liners alone every year is more than one million tons. The emergence of rubber liners is favored by many big customers in the ball mill field. What are the indexes that affect the rubber lining plate of the ball mill? 1. Conditions of ball mill use scenario The feeding particle size of ore also plays an important role, so a good ball mill rubber lining plate will be designed according to the size of the customer's mill, feeding particle size, and steel ball diameter. Select the rubber formula suitable for customers, and carry out mapping, design, testing and processing. 2. Rubber formula and processing technology: The rubber material and formula directly affect the performance of the rubber lining plate of the ball mill. Wear resistance is a key factor. It is impossible to determine how long its service life is because of the impact of industrial and mining conditions. The second is corrosion resistance. This is the characteristic of the formula, so even if the appearance is the same, the performance is an advantage. Do not buy for cheap. 3. Regular maintenance: everyone knows that the rubber lining plate of the ball mill is fixed to the cylinder by means of T-bolts, so it is also very important to regularly check the tightness of the bolts and the wear of the rubber strips inside the cylinder. In order to avoid damaging the rubber lining plate of the cylinder and the cylinder of the ball mill when the lifting strip is worn out, the gain is not worth the loss. Air compression hose Where can I find it? One of the advantages of the manganese steel lining plate is that the replacement is simple and only needs two people to operate, and it can be replaced wherever it is broken. This is an advantage that the manganese steel lining plate does not have.
At present, the common air ducts in the domestic market are generally made of galvanized iron sheet, commonly known as white iron sheet. high quality Air compression hose And the thickness is 0.44~1.22mm. The thickness of iron sheet of air duct in China is generally less than 1.5mm, and the thickness of zinc coating refers to the national standard GB/T 13912-2002: 35 μ m. Average 45 μ m。 During the production of galvanized air duct, the national standard requires us to understand the following figures: 1. Appearance: conduct appearance inspection on all hot galvanized parts, and the main surface should be smooth, free of falling off, roughness and zinc spikes (if these zinc spikes will cause damage), free of peeling, missing plating, and residual solvent residue, There shall be no zinc lump and zinc ash in the parts where hot galvanized workpieces are used or where they are corrosion resistant. Note: "Roughness" and "smoothness" are relative concepts, and the coating roughness of workpiece is different from that of mechanical roller or (and) blow molding and galvanized products (such as galvanized steel plate and galvanized steel wire). As long as the coating thickness is greater than the specified value, there may be dark or light gray uneven areas on the surface of the plated parts. White rust (mainly white or gray corrosion products of alkaline zinc oxide) is allowed on the surface of galvanized workpieces stored in wet conditions. 2. Thickness: quantitative sampling shall be carried out according to the specified test method for coating thickness test. According to the size of the main surface area of hot-dip galvanized parts, the coating thickness measured in the test shall meet the following requirements: A) For parts with the main surface area greater than 2m (i.e. large parts), the average coating thickness measured on all basic measured surfaces of each part in the sample shall not be less than the minimum value of the corresponding average coating thickness: B) For parts with the main surface area less than 2m, Air compression hose Where can I find it? The local coating thickness measured on each basic measuring surface shall not be less than the minimum local thickness, and the average coating thickness measured on all basic measuring surfaces of the sample shall not be less than the corresponding minimum average thickness.