The development trend of HVAC duct is high quality Cord hose Now more and more companies choose advanced spiral duct technology. The advantages of spiral air duct are as follows: 1. Good air tightness. Spiral air duct greatly reduces the connection of air duct and minimizes the leakage between connectors. The typical spiral air duct is 3-6m, but the typical rectangular air duct is only 1-1.5m; At the same time, only one connector is required to connect two spiral air ducts, while a typical rectangular air duct connector requires separate double flanges. 2. Standardized products. The production of spare parts (pipes and connectors) is highly automated and systematic, and has industrialized quality control. 3. Low installation cost. The installation of round duct only needs one third of that of rectangular duct. 4. Save space. Under the same pressure and the same installation space, the spiral air duct with a diameter of 200mm can replace the rectangular air duct with a diameter of 250x150mm. Without increasing the installation space, multiple spiral pipes can be used instead of wider rectangular pipes. Considering various factors, in most cases, spiral pipes require less space than rectangular pipes. Under the same pressure, the installation space of several spiral pipes is equal to or less than that of rectangular pipes. Most rectangular pipe systems require 4 bolts to fix, which will increase 40~80mm in each direction. 5. The pressure drop is low. As we know, spiral duct has lower ventilation resistance than rectangular duct. 6. Precision locking technology. Qingdao Cord hose The mold on the is made of special steel. After years of use, the surface remains unchanged, making the surface of the spiral air duct free of scratches and extending the service life. 7. The perimeter of rectangular air duct with length width ratio of 1:3 at the same section is 40% larger than that of spiral air duct, which means that spiral air duct saves more materials and reduces thermal insulation.
one Qingdao Cord hose When using, the talcum powder on the inner wall of the hose must be blown clean to prevent the channel of the welding torch from being blocked. Avoid external extrusion and mechanical damage during use, and do not fold the pipe body. 2. Care must be taken when storing and using the hose to keep it clean and free from damage. For example, avoid exposure to sunlight, rain and snow, and prevent contact with acids, alkalis, oils and other organic solvents that can damage the hose. The storage temperature shall be - 15~40 ℃, and the distance from the heat source shall not be less than 1m. 3. According to the national standards, the oxygen hose is red, the working pressure vessel is 1.5MPa, the inner diameter of the hose is 8mm, and the outer diameter is 18mm; The acetylene hose is black, the working pressure vessel is 0.3MPa, the inner diameter of the hose is 8mm, and the outer diameter is 16mm. 4. The gas cutting operation requires a large oxygen output, so the valves of the gas cylinder (or oxygen pipeline) connected to the high pressure end of the oxygen meter should be fully opened to ensure adequate flow and stable pressure. The low pressure gauge has indicated the working pressure, but the pressure drops suddenly when using oxygen. At this time, it is easy to backfire and may backfire into the oxygen hose to cause explosion. 5. Oxygen hose and acetylene hose shall not be mixed or substituted with each other, and oxygen and hose shall not be used to blow away the blockage of acetylene hose. At the same time, it is necessary to check and eliminate the defects such as gas leakage and blockage of the welding torch at any time to prevent the formation of oxygen and acetylene mixture in the hose. It should be pointed out that the hose color specified in the national standard is opposite to that specified in the international standard (ISO) (oxygen hose is black, acetylene hose is red). At the same time, it is different from the original ministerial standard (HG4-605-66) that oxygen hose is red and acetylene hose is green. Before 1966, domestic oxygen hose was black or green and acetylene hose was red. thus Cord hose Price It causes inconsistency between the understanding and habits of the supply department and the user, and is easy to cause accidents due to the mixing and substitution of rubber hoses. At present, it should be emphasized that unified understanding and use should be carried out in accordance with the provisions of national standards, and attention should be paid to distinguishing the rubber hoses of imported equipment.
You know? Qingdao Cord hose Are there reinforcement regulations and requirements? Stainless steel welded air duct is a commonly used equipment, and its reinforcement actually has regulations and requirements, do you know? If in pipe support is adopted, the spacing between each support point and the edge or flange of the air duct shall be uniform, and the value shall not be greater than 950 mm. If the corrugated bars or wires are used for reinforcement, the arrangement should be regular and the spacing should be even. Moreover, there should be no obvious deformation and other problems for the board surface. If the welded air duct is reinforced, it should be made of ribbed bars, vertical bars, angle steel, flat steel, reinforcing bars and supports inside the duct. The appropriate one can be selected according to the actual situation and needs. If angle steel or reinforcing bars are used, they should also be arranged neatly and symmetrically. The height shall not be greater than the flange width. Principles and requirements for stainless steel air duct plate connection. When the thickness is less than or equal to 1mm, the splicing of plates shall be done by biting or riveting. When the thickness of plates is greater than 1mm, argon arc welding or electric arc welding shall be used instead of gas welding. The mature argon arc welding process of "single side welding, double side forming" shall be adopted; When assembling weldments, the welding materials and process measures selected for spot welding shall be consistent with the formal Cord hose Price The requirements are the same. The misalignment deviation of the pipe butt joint is less than 20% of the wall thickness and less than 2mm. Adjust the butt joint clearance, and do not use the method of heating, tensioning and twisting the pipe. It is not allowed to strike an arc or test the current on the weldment, and the pipe surface shall be free of arc scratch and other defects. Splash prevention measures shall be taken during welding. After welding, the slag and spatter shall be cleaned with stainless steel flat shovel. After welding, the slag on the weld surface and the spatter on both sides shall be cleaned.
Let's take a look today Qingdao Cord hose How should the maintenance work be done? Firstly, the thickness of galvanized air duct splice plate shall be within the range specified in various specifications. If it is less than the thickness, it is easy to have defects such as cracking and wrinkling due to significant increase of bending force, abnormal damage of forming roll, overload of transmission system, boring, etc. Secondly, in the dedusting system: galvanized air ducts can be used for the collection and transportation of dedusting devices. In terms of air exhaust system: there is a large amount of smoke in the dining room, dining room and hotel kitchen, which needs air exhaust. The galvanized pipe is more appropriate, with good strength, economy and practicality. In air conditioning system: galvanized air duct can be pasted with thermal insulation materials, and the surface is beautiful. In bulk material transportation: in the pneumatic conveying system, some materials with fine loose particles can be transported by galvanized pipes, which has low cost and good effect. In the ventilation system: fresh air is supplied and discharged, harmful gases are discharged outdoors, and outdoor fresh air is sent indoors. The strength of stainless steel plate is greater than that of ordinary steel plate. When stainless steel plate is used for seaming, first of all, a forming test should be carried out to avoid overloading of equipment and excessive wear or mechanical problems. Due to the poor plasticity of aluminum plate, it is easy to crack when biting into forming. Forming test shall be conducted before construction. The last point is that the protection and decoration of the galvanized layer of the galvanized air duct can be significantly improved after passivation treatment, dyeing or brushing light protective agent. and Qingdao Cord hose The fire prevention function of is mainly reflected in that it is nonflammable, but it should be noted that whether the insulation layer is burned depends on the material. We recommend that galvanized air duct materials use nonflammable insulation materials such as centrifugal glass wool.
“ high quality Cord hose What are the applications in engineering transformation? " In this issue, we will explain this problem for you. Those who have consulted this problem will come to see it: First, we should consider the water supply and drainage of all water related equipment, such as wells, pumps, etc., their location, installation method and temperature, including galvanized air ducts. 2、 It is very important to consider galvanized air duct in advance to avoid temporary replacement of galvanized air duct materials. 3、 After the location of the machine tool is determined, the drainage outlet can be considered to be arranged underground, which is not only convenient but also durable. 4、 After river reconstruction, there should be a suppression test, but now many construction teams do not suppress the test. It is usually said that it is not important, that there is water and pressure in the galvanized air duct, and so on. Try to be present to suppress the test. 5. If the installation is completed, pay attention to the inspection of the workshop, water pump room and FRPP drain. If the drainage system is slow, the installation program should be able to open the installation. Water outlets should be protected, especially during civil engineering construction, Cord hose Price It may cause soil loss and blockage. I believe that you have a better understanding of this information, and we will continue to improve the galvanized air duct to make it more widely used.