“ high quality Rubber hose What are the applications in engineering transformation? " In this issue, we will explain this problem for you. Those who have consulted this problem will come to see it: First, we should consider the water supply and drainage of all water related equipment, such as wells, pumps, etc., their location, installation method and temperature, including galvanized air ducts. 2、 It is very important to consider galvanized air duct in advance to avoid temporary replacement of galvanized air duct materials. 3、 After the location of the machine tool is determined, the drainage outlet can be considered to be arranged underground, which is not only convenient but also durable. 4、 After river reconstruction, there should be a suppression test, but now many construction teams do not suppress the test. It is usually said that it is not important, that there is water and pressure in the galvanized air duct, and so on. Try to be present to suppress the test. 5. If the installation is completed, pay attention to the inspection of the workshop, water pump room and FRPP drain. If the drainage system is slow, the installation program should be able to open the installation. Water outlets should be protected, especially during civil engineering construction, Rubber hose company It may cause soil loss and blockage. I believe that you have a better understanding of this information, and we will continue to improve the galvanized air duct to make it more widely used.
How to install correctly doy Rubber hose ? In the fire smoke exhaust pipe system, the airport and air valve must use non fuel, and the thickness of citizen flue and galvanized ventilation pipe should be improperly used. The high-pressure system should be selected according to the national code GB50243. When the fire smoke exhaust fan is installed on the roof, certain maintenance measures should be taken. The exposed power line must be threaded through the conduit, and the conduit material should be combined with the metal hose or Capelli and duck neck equipment to make it curved. The fire fighting system and equipment lines must be fixed with special clamps to avoid falling. Stainless steel air duct and ventilation equipment shall be made of three fabric flame retardant materials with soft connection. It is suggested that the length should be 15-30cm, and the electrical interpenetration should be completed. Bolts require the same length. The three main bodies should be grounded, ventilation equipment, and equipment and devices between dynamic loads should be equipped with shock absorption measures. When Rubber hose company Box type pipe fittings should not be used for changing direction, variable diameter, branch road, or junction, but the wind speed of box section should not exceed 1.5m/s for air distribution and static pressure box when necessary; It is advisable to have 5-10 times the pipe diameter between conduit pipes. The length of expandable metal pipes or non-metallic soft links should not exceed 2 meters. There should be no disintegration and dead corners. During the installation process, when the length of pipe elbows and straight pipes exceeds 20 meters, add anti impact frame open room exhaust fans and add or subtract supports.
doy Rubber hose The entry threshold is low, the industry market is mixed, and small enterprises with small scale, lack of core competitiveness and low technical level can be seen everywhere. Most of these enterprises lack brand awareness, and there are many brand names and unlicensed products. It is difficult to form enterprise influence through brands, and it is more difficult to improve product added value through brands. If the metal hose wants to take the road of high-end, it must improve both inside and outside. A good brand image promotion and influence building can certainly provide a strong driving force for the development of enterprises, but the root of this driving force lies in the high quality of the metal hose products themselves. Tongfeng Metal Hose said that in the future, domestic metal hose products will focus on high precision, high efficiency, high firmness, multi-function, multi specification, multi variety standardization, serialization and generalization to show their characteristics. One of the main reasons why China's metal hoses have been in the low-end state for a long time is the lack of independent research and development of products. On the one hand, the homogenization competition is serious. In order to win consumers, metal hose enterprises have long focused on low-cost competition and low price shopping. As a result, many enterprises only focus on the production and marketing of low-end products, ignoring the upgrading and innovation of product technology. on the other hand, Rubber hose company ZHUANLI's weak awareness of protection and the serious phenomenon of technology plagiarism and infringement in the industry make the technology cost invested by many enterprises more than worth the cost, which has seriously hit the enthusiasm of metal hose enterprises for innovation.
doy Rubber hose Main impact: The air volume loss of the whole system is too large to meet the air volume requirements, and the power is seriously wasted. 1. If the stainless steel welded air duct system adopts the combined flange air duct, it may be that the seam, flange strip seam and hole seam are not sealed with sealant; The allowance of segment blanking seaming is greater than the specification requirements. 2. No embedded parts are set at the joint of brick structure air duct and metal air duct, or the sealing gap is too large or the joint is not tight. Countermeasures: 1. Button type seaming can be used for medium pressure air duct; Corner seam or joint corner seam shall be used at four corners of high-pressure air duct or clean system air duct. 2. Seams of stainless steel welded air ducts, joints without flange inserts and holes must be sealed with sealing paste to prevent air leakage. 3. During construction, embedded parts shall be set at the junction of brick, structural air duct and metal air duct as required, or the civil engineering unit shall cooperate to block and seal to ensure close connection. During the air duct anti-corrosion treatment, the next anti-corrosion treatment can be carried out after the previous paint is dried; It is strictly forbidden to work without certificate. The duct type air outlet is a central air conditioning terminal air supply system that integrates the functions of air outlet, air supply pipeline, static pressure box, thermal insulation material, air valve, etc. Rubber hose company Calculation of air duct size of stainless steel welded air duct: the equal damping method (equal pressure method) is a convenient calculation method, which is suitable for many occasions.
Before construction, the technicians must be familiar with the drawings and relevant data carefully, and understand the technological process, working medium, pressure, temperature and other technical parameters as well as the materials, models and specifications of the materials and accessories used. The construction personnel must be fully familiar with the construction procedures, construction methods, quality standards, operating procedures and safety technical requirements, and strictly implement them during construction. Main materials used for making galvanized air duct, doy Rubber hose It shall comply with the current national product standards and the enterprise standards of the manufacturer, and shall have the factory certificate and other relevant material certificates. All material accessories must be rechecked with the design and current national product standards, and shall have the factory certificate, material quality assurance and other relevant material certificates. Combined flange air duct is also called thin-walled steel plate flange air duct. It is an air duct connected by non profile steel and made of galvanized steel plate. Its connection form can be directly pressed by strips or steel plates or the air duct and flange can be integrally formed. This kind of air duct has advanced manufacturing technology, accurate blanking, low material consumption, stable product quality, many varieties, smooth contour lines, and air leakage rate far lower than the national standard, which is conducive to the production of ventilation ducts to be industrialized, large-scale, standardized and automated. It is a scientific and technological achievement project that has been vigorously promoted in China in recent years as one of the non blue air duct processes. The National Grand Theater project is to use this new process air duct. Common plate flange air duct 1 Fabrication of composite flange air duct Common mechanical equipment for fabrication of composite flange air duct include: rectangular air duct full-automatic production line, plasma automatic cutting machine, flange strip forming machine, hook code forming machine, conjoined flange forming machine, etc. The combined flange air duct is based on the air duct size given in the drawing, Rubber hose company Fully automatic production line is used to produce coiled material with a common width of 1250mm, and the plate thickness is 0.5~1.2mm. When the large side of the air duct is less than or equal to 2m, the air duct is formed into TDC1 flange, and the standard pipe length is 1170mm; When the large side of the fabricated air duct is less than or equal to 2.5m, the air duct is formed into TDC2 flange, and the standard pipe length is 1250mm; When the large side of the fabricated air duct is more than 2.5m, the air duct is formed into an angle steel flange, and the standard pipe length is 1230mm