Guangzhou rubber liner 1. The manufacturing quality shall be guaranteed according to the national standards of Oxygen Hose (GB/T2550-91) and Acetylene Hose (GB/T2551-91) respectively, and the hose shall have sufficient compressive strength and flame retardant characteristics. According to the national standard, the oxygen hose is red, the working pressure vessel is 1.5MPa, the inner diameter of the hose is 8mm, and the outer diameter is 18mm; 2. Care must be taken when storing and using the hose to keep it clean and free from damage. For example, avoid exposure to sunlight, rain and snow, and prevent contact with substances such as acid, alkali, oil and other organic solvents that can damage the hose. The storage temperature shall be - 15 ℃~40 ℃, and the distance from the personnel shall not be less than 1m; 3. When using a new hose, the talcum powder on the inner wall of the hose must be blown out first to prevent the channel of the welding torch from being blocked. Avoid external extrusion and mechanical damage during use, and do not fold the pipe body. 4. If the oxygen hose catches fire, stop the air supply first, and then deal with the fire hose, but do not bend the hose. The cylinder valve must be closed when the cylinder is not in use or after work. 5. The hose with bulge, crack or air leakage shall not be used, and the air leakage hose shall not be used after being stuck with adhesive tape. rubber liner Where can I find it? When connecting the two ends of the hose with tools, clamp or wire shall be used to fasten, and the intermediate joint shall be fastened with a gas pipe connector.
Air duct mainly refers to the ventilation duct of the central air-conditioning system, which is often ignored, but it is an important part of the air-conditioning system. Guangzhou rubber liner What are the regulations for welding air ducts? Gongfa HVAC is a manufacturer dedicated to the production of air ducts, which has been recognized and supported by the majority of users for many years. 1、 The welding regulations of carbon steel plate air duct are as follows: 1. The carbon steel plate air duct should be welded by DC welder. Introduction to welding air duct If AC welding machine is used for welding, a vibrator must be added to reduce excitation and stabilize the arc. When welding steel plates, the arc is unstable, which can lead to deterioration of weld quality. 2. Before welding, remove the dirt, oil stain and rust at the welding port; When spot welding or continuous welding is used, the oxide shall also be removed. The butt joint shall be kept with the minimum gap, and the overlap at the manual spot welding location shall be removed in time. After welding, the electrode slag and residual welding wire in the weld and its surrounding area shall be removed in time. 2、 The welding regulations of stainless steel air duct are as follows: 1. Before welding the air duct, remove the grease and dirt in the weld area to prevent pores and sand holes in the weld. Cleaning can be carried out with gasoline, acetone, etc. When welding stainless steel plates by electric arc welding, the surfaces on both sides of the weld should be coated with white ash, Guangzhou rubber liner To avoid welding slag splashes adhering to the surface of the plate. 2. After welding, attention shall be paid to removing the slag at the weld, brushing the metal luster with a copper wire brush, pickling with 10% nitric acid solution, and then cleaning with hot water.
People buy in daily life high quality rubber liner Take it home for installation. It is obviously installed very well, but the spiral air duct will become loose for a long time, which gives most users a headache. So what is the problem with spiral air duct reinforcement? This is of course necessary. The following manufacturer of galvanized spiral air duct will give you a detailed introduction. 1. Reinforcement measures shall be taken for circular pipes (excluding spiral pipes) with a diameter greater than or equal to 80 mm, a section length greater than 1250 mm or a total area greater than 4 ㎡; 2. The side length of rectangular air duct is more than 630 mm, the length of pipeline insulation side is more than 800 mm, the section length is more than 1250 mm, or the plane area of one side of low pressure pipeline is more than 1.2 m2, and that of medium and high pressure pipeline is more than 1.0 m2, so reinforcement measures should be taken; 3. For reinforcement of irregular oval pipes, the reinforcement method of rectangular pipes shall be referred to. The spiral air duct manufacturer Hongyuansheng Electromechanical also has something to say: the reinforcement of galvanized air duct non-metallic air duct should also meet the following requirements: when the diameter or side length of the rigid PVC pipe is greater than 500 mm, the connection between the pipe and the flange should be equipped with stiffening plates, and the spacing should not be greater than 450 mm. The reinforcement of organic and inorganic FRP pipes shall be made of the same materials with the same anti-corrosion performance as the pipes themselves. rubber liner Where can I find it? The manufacture of rectangular pipe elbows shall generally adopt concentric arc elbows with the curvature radius of the length inside and outside the plane. When other forms of elbow are used, and the plane length is more than 500 mm, the elbow deflector shall be set.
We all know rubber liner Where can I find it? The noise pollution in industrial production is very serious, and noise pollution is also an important factor affecting workers' enthusiasm for production. Ball mills were once a major source of noise in mining equipment. In order to reduce the noise generated by ball mills, protect the physical and mental health of workers, improve workers' enthusiasm for production, and create greater profits for the company, Through the efforts and research of domestic and foreign industry experts, the ball mill liner has been transformed. Through repeated tests and comparison, it is found that the noise generated by the rubber liner and the manganese steel liner of the ball mill is far less than the manganese steel liner when the technical parameters are up to standard. According to the data provided by the noise monitoring station and the concentrator, We analyzed the noise intensity and the economic benefits: the domestic ND2 precision sound level meter and octave filter were used for detection, and the sound level meter was calibrated by the provincial sound level meter measurement and verification station; There is no sound insulation room in the ball mill workshop. The monitoring points are arranged according to the position of the ball mill and the flow of workers to observe the mechanical operation, 2m away from the sound source. One monitoring point is respectively set on the left and right of the east and west of the workshop and in the middle of the two ball mills. The measurement method is in accordance with the Noise Detection Specification for Industrial Enterprises. As the noise in the workshop is continuous and steady, sound level A is used as the evaluation basis. The rubber lining plate is manufactured by Hainan Rubber Lining Plate Factory according to the ball mill shell structure and the original manganese steel lining plate specification (1.4mx0.74mX0.07m). Guangzhou rubber liner First, take out the manganese steel lining plate in the ball mill barrel, and then install the rubber lining plate in the barrel in turn (front and back). Each ball mill is installed with 48 pieces. First, use the pressure strip to compress, and then use the screws to fix the rubber lining plate on the ball mill barrel, so as to prevent falling off when rotating. The noise intensity of the ball mill workshop with manganese steel liner is 94-103dB (A), while the noise intensity of the ball mill workshop with rubber liner is 87-92dB (A), and the noise reduction difference is 7-11dB (A). The rubber liner has good noise reduction effect.
rubber liner Where can I find it? Precautions ① The acid and alkali resistant rubber hose used shall not only be oil resistant, but also be pressure resistant, heat resistant, cold resistant, wear resistant and aging resistant. ② The rubber hose should not be too long or too short, generally 1.4 meters. ③ The interface is tight and can be fastened with thin iron wire or clip to prevent falling off and air leakage. ④ It is forbidden to pull acid and alkali resistant rubber hose from one room to another or through walls, floors and floors to prevent accidents caused by rubber hose breaking and falling off. ⑤) The acid and alkali resistant rubber hose should be placed in a place where it can be seen frequently, so that it is easy to detect leakage. Check whether the rubber hose leaks after each bottle change. ⑥ Do not replace acid and alkali resistant rubber hose with universal rubber hose. Since the full rubber hose does not contain a skeleton layer, it is only necessary to use a press out machine to press out the hose; The cloth clamping hose needs to use a molding machine that wraps the adhesive tape on the inner adhesive layer; When forming the suction hose, first wrap the metal spiral wire and then wrap the inner rubber; Special fabric knitting machine or winding machine shall be used for knitting and winding hose; Knitting machine is required for knitting hose. Guangzhou rubber liner The basic production processes include rubber mix processing, cord fabric and canvas processing, rubber tube molding, vulcanization, etc. The manufacturer of acid and alkali resistant rubber hose said that the processing method of the skeleton layer and the forming equipment of the rubber hose are different for different structures and different skeletons.
You know? Guangzhou rubber liner Are there reinforcement regulations and requirements? Stainless steel welded air duct is a commonly used equipment, and its reinforcement actually has regulations and requirements, do you know? If in pipe support is adopted, the spacing between each support point and the edge or flange of the air duct shall be uniform, and the value shall not be greater than 950 mm. If the corrugated bars or wires are used for reinforcement, the arrangement should be regular and the spacing should be even. Moreover, there should be no obvious deformation and other problems for the board surface. If the welded air duct is reinforced, it should be made of ribbed bars, vertical bars, angle steel, flat steel, reinforcing bars and supports inside the duct. The appropriate one can be selected according to the actual situation and needs. If angle steel or reinforcing bars are used, they should also be arranged neatly and symmetrically. The height shall not be greater than the flange width. Principles and requirements for stainless steel air duct plate connection. When the thickness is less than or equal to 1mm, the splicing of plates shall be done by biting or riveting. When the thickness of plates is greater than 1mm, argon arc welding or electric arc welding shall be used instead of gas welding. The mature argon arc welding process of "single side welding, double side forming" shall be adopted; When assembling weldments, the welding materials and process measures selected for spot welding shall be consistent with the formal rubber liner Where can I find it? The requirements are the same. The misalignment deviation of the pipe butt joint is less than 20% of the wall thickness and less than 2mm. Adjust the butt joint clearance, and do not use the method of heating, tensioning and twisting the pipe. It is not allowed to strike an arc or test the current on the weldment, and the pipe surface shall be free of arc scratch and other defects. Splash prevention measures shall be taken during welding. After welding, the slag and spatter shall be cleaned with stainless steel flat shovel. After welding, the slag on the weld surface and the spatter on both sides shall be cleaned.