The air conditioning in the hall of a giant building is provided by the 6FWB unit fixed in the basement. high quality Acetylene tape The vibration of the unit is transmitted to the ground hall through the bridge connecting the sand blasting hose pipe, and the noise value reaches 45dB. In such an environment, people always feel uncomfortable. After the improved design, sandblasting rubber pipes were connected in series on the connecting pipes, which not only absorbed some of the noise generated by the unit vibration, but also the noise generated by the fluid pulsation in the pipeline system. At this time, the noise value in the ground hall was only 33dB, greatly improving the environment in the hall. The movable cylinder on the vulcanizing press will move upward and downward for the need of loading and unloading the mold. After repeated reciprocating movements, the copper serpentine will suffer from fatigue fracture. Although it can still be used after repair, it will cause time loss if it is stopped for repair. Acetylene tape company Although it has good soft properties and strong fatigue resistance, it is weak in pressure bearing, temperature resistance, aging resistance and other aspects, and can not continue after several months of use. The good comprehensive performance of sand blasting hose is fully reflected here. In the general industrial field, in addition to pressure and temperature, there are often severe conditions such as fatigue, corrosion, vibration, compression, impact, etc. Under such circumstances, it is most appropriate to use sandblasting hose to compensate for the position movement of the pipeline.
Shangrao Acetylene tape The structure is composed of liquid resistant synthetic rubber inner rubber layer, medium rubber layer, I or II or III steel wire braid reinforcement layer, and weather resistant synthetic rubber outer rubber layer. Sand pumping hose features: 1. Sand pumping hose is made of special synthetic rubber, which has excellent oil resistance, heat resistance and aging resistance. 2. The rubber hose has high bearing pressure and excellent pulse performance. 3. The pipe body is tightly combined, soft to use, and has little deformation under pressure. 4. Sand pumping hose has excellent bending resistance and fatigue resistance. 5. The sand pumping hose is long, φ 20 meters above 32, φ Below 25 meters, it can reach 10 meters or even 100 meters. Sand pumping hose parameters: 1. The inner wall of nylon cord hose is smooth with little friction. Reinforcing layer: high-strength synthetic wire, spiral winding of steel wire and iron wire (sand suction pipe) 2 high quality Acetylene tape Flange connection (ANSI150 standard flange) 3. Nominal pressure: 20BAR4, temperature: - 50 ℃ -+95 ℃ 5. Working pressure of sand suction hose and mud discharge pipe: positive pressure: 10kg; Test pressure: working negative pressure of 15kg steel ring sand suction hose: ≥ 15kg sand suction hose has strong flexibility, which is mainly used as the sand pump sand discharge pipe to connect the sand transport pipe and sand pump, as well as the pipe connection bend.
one Shangrao Acetylene tape When using, the talcum powder on the inner wall of the hose must be blown clean to prevent the channel of the welding torch from being blocked. Avoid external extrusion and mechanical damage during use, and do not fold the pipe body. 2. Care must be taken when storing and using the hose to keep it clean and free from damage. For example, avoid exposure to sunlight, rain and snow, and prevent contact with acids, alkalis, oils and other organic solvents that can damage the hose. The storage temperature shall be - 15~40 ℃, and the distance from the heat source shall not be less than 1m. 3. According to the national standards, the oxygen hose is red, the working pressure vessel is 1.5MPa, the inner diameter of the hose is 8mm, and the outer diameter is 18mm; The acetylene hose is black, the working pressure vessel is 0.3MPa, the inner diameter of the hose is 8mm, and the outer diameter is 16mm. 4. The gas cutting operation requires a large oxygen output, so the valves of the gas cylinder (or oxygen pipeline) connected to the high pressure end of the oxygen meter should be fully opened to ensure adequate flow and stable pressure. The low pressure gauge has indicated the working pressure, but the pressure drops suddenly when using oxygen. At this time, it is easy to backfire and may backfire into the oxygen hose to cause explosion. 5. Oxygen hose and acetylene hose shall not be mixed or substituted with each other, and oxygen and hose shall not be used to blow away the blockage of acetylene hose. At the same time, it is necessary to check and eliminate the defects such as gas leakage and blockage of the welding torch at any time to prevent the formation of oxygen and acetylene mixture in the hose. It should be pointed out that the hose color specified in the national standard is opposite to that specified in the international standard (ISO) (oxygen hose is black, acetylene hose is red). At the same time, it is different from the original ministerial standard (HG4-605-66) that oxygen hose is red and acetylene hose is green. Before 1966, domestic oxygen hose was black or green and acetylene hose was red. thus Acetylene tape company It causes inconsistency between the understanding and habits of the supply department and the user, and is easy to cause accidents due to the mixing and substitution of rubber hoses. At present, it should be emphasized that unified understanding and use should be carried out in accordance with the provisions of national standards, and attention should be paid to distinguishing the rubber hoses of imported equipment.
Let's take a look today Shangrao Acetylene tape How should the maintenance work be done? Firstly, the thickness of galvanized air duct splice plate shall be within the range specified in various specifications. If it is less than the thickness, it is easy to have defects such as cracking and wrinkling due to significant increase of bending force, abnormal damage of forming roll, overload of transmission system, boring, etc. Secondly, in the dedusting system: galvanized air ducts can be used for the collection and transportation of dedusting devices. In terms of air exhaust system: there is a large amount of smoke in the dining room, dining room and hotel kitchen, which needs air exhaust. The galvanized pipe is more appropriate, with good strength, economy and practicality. In air conditioning system: galvanized air duct can be pasted with thermal insulation materials, and the surface is beautiful. In bulk material transportation: in the pneumatic conveying system, some materials with fine loose particles can be transported by galvanized pipes, which has low cost and good effect. In the ventilation system: fresh air is supplied and discharged, harmful gases are discharged outdoors, and outdoor fresh air is sent indoors. The strength of stainless steel plate is greater than that of ordinary steel plate. When stainless steel plate is used for seaming, first of all, a forming test should be carried out to avoid overloading of equipment and excessive wear or mechanical problems. Due to the poor plasticity of aluminum plate, it is easy to crack when biting into forming. Forming test shall be conducted before construction. The last point is that the protection and decoration of the galvanized layer of the galvanized air duct can be significantly improved after passivation treatment, dyeing or brushing light protective agent. and Shangrao Acetylene tape The fire prevention function of is mainly reflected in that it is nonflammable, but it should be noted that whether the insulation layer is burned depends on the material. We recommend that galvanized air duct materials use nonflammable insulation materials such as centrifugal glass wool.
You know? Shangrao Acetylene tape Are there reinforcement regulations and requirements? Stainless steel welded air duct is a commonly used equipment, and its reinforcement actually has regulations and requirements, do you know? If in pipe support is adopted, the spacing between each support point and the edge or flange of the air duct shall be uniform, and the value shall not be greater than 950 mm. If the corrugated bars or wires are used for reinforcement, the arrangement should be regular and the spacing should be even. Moreover, there should be no obvious deformation and other problems for the board surface. If the welded air duct is reinforced, it should be made of ribbed bars, vertical bars, angle steel, flat steel, reinforcing bars and supports inside the duct. The appropriate one can be selected according to the actual situation and needs. If angle steel or reinforcing bars are used, they should also be arranged neatly and symmetrically. The height shall not be greater than the flange width. Principles and requirements for stainless steel air duct plate connection. When the thickness is less than or equal to 1mm, the splicing of plates shall be done by biting or riveting. When the thickness of plates is greater than 1mm, argon arc welding or electric arc welding shall be used instead of gas welding. The mature argon arc welding process of "single side welding, double side forming" shall be adopted; When assembling weldments, the welding materials and process measures selected for spot welding shall be consistent with the formal Acetylene tape company The requirements are the same. The misalignment deviation of the pipe butt joint is less than 20% of the wall thickness and less than 2mm. Adjust the butt joint clearance, and do not use the method of heating, tensioning and twisting the pipe. It is not allowed to strike an arc or test the current on the weldment, and the pipe surface shall be free of arc scratch and other defects. Splash prevention measures shall be taken during welding. After welding, the slag and spatter shall be cleaned with stainless steel flat shovel. After welding, the slag on the weld surface and the spatter on both sides shall be cleaned.