Many people have never understood wear-resisting rubber liner It is better to use cast iron or rubber lining plate, so today I will give you a detailed analysis. The lining plate of the ball mill can tell you for sure that it is better to use rubber lining plate, which is also a trend for rubber lining plate to replace manganese steel lining plate. The rubber lining plate has many advantages that can not be achieved by manganese steel lining plates such as cast iron, so it has more advantages. One of the advantages of using cast iron or rubber liner for ball mill liner is that the noise of rubber liner is lower. In the process of grinding the rubber lining plate with materials, the noise is lower because it is not directly rubbed. Moreover, the rubber lining plate can throw the steel ball up for the second time to form the second grinding of materials, which makes the grinding of materials more thorough and the grinding fineness more uniform with good effect. In addition, the rubber lining plate can reduce the noise by an average of 30 dB compared with the noise of the cast iron lining plate, making it acceptable. Another important reason is energy saving. Energy consumption is an unavoidable problem for users of ball mills, because the cast iron lining plate is heavy in quality, rubber liner company Therefore, when the motor drives the lining plate, it will consume a lot of power. The rubber used by the rubber lining plate itself is light, so the electric energy consumed by the motor when driving is very small, which can be more than 10000 yuan of electric energy a year.
People buy in daily life wear-resisting rubber liner Take it home for installation. It is obviously installed very well, but the spiral air duct will become loose for a long time, which gives most users a headache. So what is the problem with spiral air duct reinforcement? This is of course necessary. The following manufacturer of galvanized spiral air duct will give you a detailed introduction. 1. Reinforcement measures shall be taken for circular pipes (excluding spiral pipes) with a diameter greater than or equal to 80 mm, a section length greater than 1250 mm or a total area greater than 4 ㎡; 2. The side length of rectangular air duct is more than 630 mm, the length of pipeline insulation side is more than 800 mm, the section length is more than 1250 mm, or the plane area of one side of low pressure pipeline is more than 1.2 m2, and that of medium and high pressure pipeline is more than 1.0 m2, so reinforcement measures should be taken; 3. For reinforcement of irregular oval pipes, the reinforcement method of rectangular pipes shall be referred to. The spiral air duct manufacturer Hongyuansheng Electromechanical also has something to say: the reinforcement of galvanized air duct non-metallic air duct should also meet the following requirements: when the diameter or side length of the rigid PVC pipe is greater than 500 mm, the connection between the pipe and the flange should be equipped with stiffening plates, and the spacing should not be greater than 450 mm. The reinforcement of organic and inorganic FRP pipes shall be made of the same materials with the same anti-corrosion performance as the pipes themselves. rubber liner company The manufacture of rectangular pipe elbows shall generally adopt concentric arc elbows with the curvature radius of the length inside and outside the plane. When other forms of elbow are used, and the plane length is more than 500 mm, the elbow deflector shall be set.
Nantong rubber liner Prevention of vibration and noise during installation: the prevention of vibration and noise during installation is a key point in the installation process. The prevention of vibration and noise of spiral air duct during installation is mainly from the following aspects: 1. The fan and spiral air duct are connected by hose, and the hose at the suction inlet of the fan shall be installed with appropriate tightness, Avoid noise and vibration caused by reducing the area of air inlet and outlet due to loose soft connection. 2. The spiral air duct shall be made, installed and connected with the components. The connection shall be tight to reduce the gap and avoid air leakage noise. 3 In order to prevent the spiral air duct from vibration, fixed supports shall be installed at the turning of each system spiral air duct and at the connection with the ventilator and the air outlet for shock absorption. 4 The vibration damping device shall be set according to the design requirements or construction specifications during fan installation. Air leakage rate test of spiral air duct After the installation of spiral air duct, air leakage rate test is required. According to the specifications, the air leakage rate test of spiral air duct adopts the combination of light leakage legality and quantitative air leakage rate test. The light leakage method is suitable for the tightness test of medium and low pressure systems; The air leakage rate test is suitable for sampling inspection of medium pressure system and full detection of high pressure system. Light leak detection of spiral air duct Light leak detection is a qualitative method to detect the tightness of the spiral air duct of the system by using the strong penetration of light to holes. The test method is to use a bulb with protective cover whose voltage is not higher than 36V and power is more than 100W in the spiral air duct on a certain length of spiral air duct in dark environment, and slowly move from one end of the spiral air duct to the other end. If light can be observed outside the spiral air duct during the test, it indicates that there is a leak point in the spiral air duct, and repair the leak point of the spiral air duct. rubber liner company The light leak detection method of the low-pressure system adopts the method of subsection detection and summary analysis. The spiral air duct of the tested system is not allowed to have multiple obvious light leaks in the form of slits. The spiral air duct of the low-pressure system has no more than two light leak points every 10 meters, and the average joint of 100 meters is no more than 16; For every 10 joints of spiral air duct of medium pressure system, no more than 1 light leak point, and no more than 8 joints per 100 meters are qualified.
The development trend of HVAC duct is wear-resisting rubber liner Now more and more companies choose advanced spiral duct technology. The advantages of spiral air duct are as follows: 1. Good air tightness. Spiral air duct greatly reduces the connection of air duct and minimizes the leakage between connectors. The typical spiral air duct is 3-6m, but the typical rectangular air duct is only 1-1.5m; At the same time, only one connector is required to connect two spiral air ducts, while a typical rectangular air duct connector requires separate double flanges. 2. Standardized products. The production of spare parts (pipes and connectors) is highly automated and systematic, and has industrialized quality control. 3. Low installation cost. The installation of round duct only needs one third of that of rectangular duct. 4. Save space. Under the same pressure and the same installation space, the spiral air duct with a diameter of 200mm can replace the rectangular air duct with a diameter of 250x150mm. Without increasing the installation space, multiple spiral pipes can be used instead of wider rectangular pipes. Considering various factors, in most cases, spiral pipes require less space than rectangular pipes. Under the same pressure, the installation space of several spiral pipes is equal to or less than that of rectangular pipes. Most rectangular pipe systems require 4 bolts to fix, which will increase 40~80mm in each direction. 5. The pressure drop is low. As we know, spiral duct has lower ventilation resistance than rectangular duct. 6. Precision locking technology. Nantong rubber liner The mold on the is made of special steel. After years of use, the surface remains unchanged, making the surface of the spiral air duct free of scratches and extending the service life. 7. The perimeter of rectangular air duct with length width ratio of 1:3 at the same section is 40% larger than that of spiral air duct, which means that spiral air duct saves more materials and reduces thermal insulation.