Texas Suction pipe Prevention of vibration and noise during installation: the prevention of vibration and noise during installation is a key point in the installation process. The prevention of vibration and noise of spiral air duct during installation is mainly from the following aspects: 1. The fan and spiral air duct are connected by hose, and the hose at the suction inlet of the fan shall be installed with appropriate tightness, Avoid noise and vibration caused by reducing the area of air inlet and outlet due to loose soft connection. 2. The spiral air duct shall be made, installed and connected with the components. The connection shall be tight to reduce the gap and avoid air leakage noise. 3 In order to prevent the spiral air duct from vibration, fixed supports shall be installed at the turning of each system spiral air duct and at the connection with the ventilator and the air outlet for shock absorption. 4 The vibration damping device shall be set according to the design requirements or construction specifications during fan installation. Air leakage rate test of spiral air duct After the installation of spiral air duct, air leakage rate test is required. According to the specifications, the air leakage rate test of spiral air duct adopts the combination of light leakage legality and quantitative air leakage rate test. The light leakage method is suitable for the tightness test of medium and low pressure systems; The air leakage rate test is suitable for sampling inspection of medium pressure system and full detection of high pressure system. Light leak detection of spiral air duct Light leak detection is a qualitative method to detect the tightness of the spiral air duct of the system by using the strong penetration of light to holes. The test method is to use a bulb with protective cover whose voltage is not higher than 36V and power is more than 100W in the spiral air duct on a certain length of spiral air duct in dark environment, and slowly move from one end of the spiral air duct to the other end. If light can be observed outside the spiral air duct during the test, it indicates that there is a leak point in the spiral air duct, and repair the leak point of the spiral air duct. Suction pipe Where can I find it? The light leak detection method of the low-pressure system adopts the method of subsection detection and summary analysis. The spiral air duct of the tested system is not allowed to have multiple obvious light leaks in the form of slits. The spiral air duct of the low-pressure system has no more than two light leak points every 10 meters, and the average joint of 100 meters is no more than 16; For every 10 joints of spiral air duct of medium pressure system, no more than 1 light leak point, and no more than 8 joints per 100 meters are qualified.
one Texas Suction pipe When using, the talcum powder on the inner wall of the hose must be blown clean to prevent the channel of the welding torch from being blocked. Avoid external extrusion and mechanical damage during use, and do not fold the pipe body. 2. Care must be taken when storing and using the hose to keep it clean and free from damage. For example, avoid exposure to sunlight, rain and snow, and prevent contact with acids, alkalis, oils and other organic solvents that can damage the hose. The storage temperature shall be - 15~40 ℃, and the distance from the heat source shall not be less than 1m. 3. According to the national standards, the oxygen hose is red, the working pressure vessel is 1.5MPa, the inner diameter of the hose is 8mm, and the outer diameter is 18mm; The acetylene hose is black, the working pressure vessel is 0.3MPa, the inner diameter of the hose is 8mm, and the outer diameter is 16mm. 4. The gas cutting operation requires a large oxygen output, so the valves of the gas cylinder (or oxygen pipeline) connected to the high pressure end of the oxygen meter should be fully opened to ensure adequate flow and stable pressure. The low pressure gauge has indicated the working pressure, but the pressure drops suddenly when using oxygen. At this time, it is easy to backfire and may backfire into the oxygen hose to cause explosion. 5. Oxygen hose and acetylene hose shall not be mixed or substituted with each other, and oxygen and hose shall not be used to blow away the blockage of acetylene hose. At the same time, it is necessary to check and eliminate the defects such as gas leakage and blockage of the welding torch at any time to prevent the formation of oxygen and acetylene mixture in the hose. It should be pointed out that the hose color specified in the national standard is opposite to that specified in the international standard (ISO) (oxygen hose is black, acetylene hose is red). At the same time, it is different from the original ministerial standard (HG4-605-66) that oxygen hose is red and acetylene hose is green. Before 1966, domestic oxygen hose was black or green and acetylene hose was red. thus Suction pipe Where can I find it? It causes inconsistency between the understanding and habits of the supply department and the user, and is easy to cause accidents due to the mixing and substitution of rubber hoses. At present, it should be emphasized that unified understanding and use should be carried out in accordance with the provisions of national standards, and attention should be paid to distinguishing the rubber hoses of imported equipment.
Texas Suction pipe Also called pu steel wire pipe, ventilation pipe, dust removal pipe, dust collection pipe, dust conveying pipe, industrial powder dust collection pipe, sweeping car dust collection pipe, drilling machine dust collection pipe, woodworking dust collection pipe, collectively called dust collection pipe. Therefore, industrial food dust transportation and industrial dust transportation are used for dust collection pipe. The production process structure of copper plated steel wire dust collection pipe is to wrap the pipe wall with solid elastic copper plated steel wire spirally, and the pipe wall material is coated with copper plated steel wire with special polyether PUR. PUR material is also called PU material. The thickness of pipe wall can be 0.4mm, 0.6mm, 0.9mm, 1.2mm, 1.5mm, 1.8mm and 2.1mm, depending on the customer's needs. Such as the temperature, wear resistance, flexibility and bending, hydrolysis resistance of the dust collection pipe. It is also necessary to consider whether static electricity is generated in the process of pipe full conveying dust to avoid unnecessary dust explosion and fire. Copper plated steel wire plastic coated dust collection tube is suitable for vacuum suction of powder and particle in industrial and mining, agriculture and water conservancy, civil engineering, food, petroleum, chemical industry, health and other industries, as well as transportation of water, oil, chemical materials, food, etc. Abrasive solids such as dust, powder, fiber, chip and particle, gas and liquid environment, for dedusting and suction plant, Suction pipe Where can I find it? Industrial vacuum cleaners, paper and textile fibers, are used as protective tubes. It is widely used in farmland irrigation, industry and mining, oil depot, sand extraction, sand blasting, food, medicine, indoor gas, powder, dust absorption and emission and other fields. This product is a substitute for PVC, rubber and metal pipes.
Now on the market Texas Suction pipe There are various models of galvanized air ducts. I believe you are familiar with galvanized air ducts. Do you know the main characteristics of galvanized air ducts? If you don't know, you can have a look. It will be helpful to purchase and use galvanized air ducts in the future. Galvanized air ducts refer to air supply, exhaust and smoke exhaust ducts used in hotels, shopping malls, textiles, chemical fiber, petrochemical, machinery manufacturing, instruments, electronics, medicine, tobacco, food, medical care, storage, office buildings, subway, civil air defense, basement and other projects. Its thickness and specification can vary according to requirements. Generally, when connecting, both ends of the galvanized spiral air duct are always externally connected to the accessories. Galvanized air duct metal air duct is made of various metal materials, commonly including galvanized iron sheet and stainless steel. With the continuous development of the tank industry at present, more and more industries and enterprises have applied to the tank industry, and more and more enterprises have entered the tank industry. Composite air ducts are composed of various inorganic materials, which can be divided into various types according to their composition, but most of them are lightweight, porous, and have large thermal resistance. First of all, the galvanized air duct is exquisite, compact, durable, beautiful, noble and elegant. The support and hanger of iron sheet air duct should be in the form and specification suitable for strength and rigidity according to the national standard atlas and specifications. The supports and hangers of extra wide, overweight and other special iron sheet air ducts with diameter or side length greater than 2500 mm shall be in accordance with the design regulations. Suction pipe Where can I find it? High quality galvanized sheet is used. Condensate water pan is molded by molding process. There are no welding seams, welding spots, and thermal insulation materials (applied to industry and buildings) that meet the fire protection standards are connected to the water pan as a whole. The galvanized air duct is small in size, and the installation of drainage pipes and lines is simple and convenient. The left and right connecting pipes and return air modes can be changed at any time to match the site conditions. Galvanized air duct can be installed in any space.