Let's take a look today Qin'an Steel wire/transparent tube How should the maintenance work be done? Firstly, the thickness of galvanized air duct splice plate shall be within the range specified in various specifications. If it is less than the thickness, it is easy to have defects such as cracking and wrinkling due to significant increase of bending force, abnormal damage of forming roll, overload of transmission system, boring, etc. Secondly, in the dedusting system: galvanized air ducts can be used for the collection and transportation of dedusting devices. In terms of air exhaust system: there is a large amount of smoke in the dining room, dining room and hotel kitchen, which needs air exhaust. The galvanized pipe is more appropriate, with good strength, economy and practicality. In air conditioning system: galvanized air duct can be pasted with thermal insulation materials, and the surface is beautiful. In bulk material transportation: in the pneumatic conveying system, some materials with fine loose particles can be transported by galvanized pipes, which has low cost and good effect. In the ventilation system: fresh air is supplied and discharged, harmful gases are discharged outdoors, and outdoor fresh air is sent indoors. The strength of stainless steel plate is greater than that of ordinary steel plate. When stainless steel plate is used for seaming, first of all, a forming test should be carried out to avoid overloading of equipment and excessive wear or mechanical problems. Due to the poor plasticity of aluminum plate, it is easy to crack when biting into forming. Forming test shall be conducted before construction. The last point is that the protection and decoration of the galvanized layer of the galvanized air duct can be significantly improved after passivation treatment, dyeing or brushing light protective agent. and Qin'an Steel wire/transparent tube The fire prevention function of is mainly reflected in that it is nonflammable, but it should be noted that whether the insulation layer is burned depends on the material. We recommend that galvanized air duct materials use nonflammable insulation materials such as centrifugal glass wool.
Qin'an Steel wire/transparent tube The break of the sandblasting hose usually refers to the appearance and change of the crack of the sandblasting hose. The sandblasting hose has one or more cracks, but the cracks are neat. Another is that the internal bending cracks at the crack of the sandblasting hose are neat. The causes of different errors are different, and the treatment methods are also different. Therefore, in the process of using or protecting the sandblasting hose, the sandblasting hose should not be subject to changing torque. When installing the sandblasting hose, try to keep the axis of the two joints on the same plane to avoid twisting the sandblasting hose in use. Therefore, be careful with the application, and try not to make the sandblasting hose change excessively to avoid consumption. Sand blasting hose plays a very important role in the industry. Its inner rubber layer is added with carbon black, which can effectively eliminate static electricity and directly contact with compressed air and abrasives. The requirement for wear resistance is quite high. Once worn through, the reinforcement layer will be exposed, and the sand blasting hose will burst. The reinforcing layer of sandblasting hose is a pressure resistant layer, so production Steel wire/transparent tube The material and layout of the reinforcement layer directly determine the pressure rating of the sandblasting hose. There are two common enhancement layers: cloth clip enhancement layer and surround enhancement layer. The sand blasting hose with an inner diameter of 50mm or more is mostly used in the construction occasions where the sand blasting pipe needs to be extended to reduce the pressure loss in the sand blasting hose and ensure the normal operation of shot blasting.
production Steel wire/transparent tube 1. During the molding of rubber products, the cohesive force of the elastomer cannot be eliminated due to the large pressure pressing. During the molding and mold release, extremely unstable shrinkage (the shrinkage rate of rubber varies due to different rubber types) often occurs. It must take a period of time before it can be gentle and stable. Therefore, at the beginning of the design of a rubber product, no matter the formula or the mold, it is necessary to carefully calculate the matching. If not, it is easy to cause dimensional instability of the product, resulting in low product quality. 2. Rubber belongs to thermosetting elastomer, while plastic belongs to thermosetting elastomer. Due to different sulfide types, the temperature range of rubber molding and curing is quite different, even affected by climate change and indoor temperature and humidity. Therefore, the production conditions of rubber products need to be properly adjusted at any time. If not, there may be differences in product quality. 3. The rubber product is the rubber mixture made from rubber raw materials after mixing in the internal mixer as the raw material. The formula is designed according to the characteristics of the required rubber products during mixing, and the required product hardness is determined. The product is molded by the rubber plate vulcanizer. After the product is formed, flash processing shall be carried out to make the product surface smooth without burrs. 4. The aging test of rubber products belongs to the category of aging test. Rubber aging refers to the phenomenon that the performance and structure of rubber and products are changed due to the combined effect of internal and external factors in the process of processing, storage and use, thus losing their use value. Steel wire/transparent tube Price It is characterized by cracking, tackiness, hardening, softening, chalking, discoloration, mildew, etc. The following conditions shall be met when the ball mill uses the rubber lining plate: 1. The hardness of the ground material. The iron base alloy is similar to the rubber lining plate for materials below medium hardness, and the rubber lining plate is superior for materials above medium hardness. 2. The temperature of rubber lining plate is generally 70 ℃ - 90 ℃, and it can reach 110-130 ℃ under special circumstances. The temperature should be lower during dry grinding. 3. Feed size. Generally, the ball mill shall be more than 20-25mm; For the autogenous mill, the feeding particle size can be larger because no steel ball is added.
Now on the market Qin'an Steel wire/transparent tube There are various models of galvanized air ducts. I believe you are familiar with galvanized air ducts. Do you know the main characteristics of galvanized air ducts? If you don't know, you can have a look. It will be helpful to purchase and use galvanized air ducts in the future. Galvanized air ducts refer to air supply, exhaust and smoke exhaust ducts used in hotels, shopping malls, textiles, chemical fiber, petrochemical, machinery manufacturing, instruments, electronics, medicine, tobacco, food, medical care, storage, office buildings, subway, civil air defense, basement and other projects. Its thickness and specification can vary according to requirements. Generally, when connecting, both ends of the galvanized spiral air duct are always externally connected to the accessories. Galvanized air duct metal air duct is made of various metal materials, commonly including galvanized iron sheet and stainless steel. With the continuous development of the tank industry at present, more and more industries and enterprises have applied to the tank industry, and more and more enterprises have entered the tank industry. Composite air ducts are composed of various inorganic materials, which can be divided into various types according to their composition, but most of them are lightweight, porous, and have large thermal resistance. First of all, the galvanized air duct is exquisite, compact, durable, beautiful, noble and elegant. The support and hanger of iron sheet air duct should be in the form and specification suitable for strength and rigidity according to the national standard atlas and specifications. The supports and hangers of extra wide, overweight and other special iron sheet air ducts with diameter or side length greater than 2500 mm shall be in accordance with the design regulations. Steel wire/transparent tube Price High quality galvanized sheet is used. Condensate water pan is molded by molding process. There are no welding seams, welding spots, and thermal insulation materials (applied to industry and buildings) that meet the fire protection standards are connected to the water pan as a whole. The galvanized air duct is small in size, and the installation of drainage pipes and lines is simple and convenient. The left and right connecting pipes and return air modes can be changed at any time to match the site conditions. Galvanized air duct can be installed in any space.
The development trend of HVAC duct is production Steel wire/transparent tube Now more and more companies choose advanced spiral duct technology. The advantages of spiral air duct are as follows: 1. Good air tightness. Spiral air duct greatly reduces the connection of air duct and minimizes the leakage between connectors. The typical spiral air duct is 3-6m, but the typical rectangular air duct is only 1-1.5m; At the same time, only one connector is required to connect two spiral air ducts, while a typical rectangular air duct connector requires separate double flanges. 2. Standardized products. The production of spare parts (pipes and connectors) is highly automated and systematic, and has industrialized quality control. 3. Low installation cost. The installation of round duct only needs one third of that of rectangular duct. 4. Save space. Under the same pressure and the same installation space, the spiral air duct with a diameter of 200mm can replace the rectangular air duct with a diameter of 250x150mm. Without increasing the installation space, multiple spiral pipes can be used instead of wider rectangular pipes. Considering various factors, in most cases, spiral pipes require less space than rectangular pipes. Under the same pressure, the installation space of several spiral pipes is equal to or less than that of rectangular pipes. Most rectangular pipe systems require 4 bolts to fix, which will increase 40~80mm in each direction. 5. The pressure drop is low. As we know, spiral duct has lower ventilation resistance than rectangular duct. 6. Precision locking technology. Qin'an Steel wire/transparent tube The mold on the is made of special steel. After years of use, the surface remains unchanged, making the surface of the spiral air duct free of scratches and extending the service life. 7. The perimeter of rectangular air duct with length width ratio of 1:3 at the same section is 40% larger than that of spiral air duct, which means that spiral air duct saves more materials and reduces thermal insulation.