Many people have never understood wear-resisting rubber liner It is better to use cast iron or rubber lining plate, so today I will give you a detailed analysis. The lining plate of the ball mill can tell you for sure that it is better to use rubber lining plate, which is also a trend for rubber lining plate to replace manganese steel lining plate. The rubber lining plate has many advantages that can not be achieved by manganese steel lining plates such as cast iron, so it has more advantages. One of the advantages of using cast iron or rubber liner for ball mill liner is that the noise of rubber liner is lower. In the process of grinding the rubber lining plate with materials, the noise is lower because it is not directly rubbed. Moreover, the rubber lining plate can throw the steel ball up for the second time to form the second grinding of materials, which makes the grinding of materials more thorough and the grinding fineness more uniform with good effect. In addition, the rubber lining plate can reduce the noise by an average of 30 dB compared with the noise of the cast iron lining plate, making it acceptable. Another important reason is energy saving. Energy consumption is an unavoidable problem for users of ball mills, because the cast iron lining plate is heavy in quality, rubber liner company Therefore, when the motor drives the lining plate, it will consume a lot of power. The rubber used by the rubber lining plate itself is light, so the electric energy consumed by the motor when driving is very small, which can be more than 10000 yuan of electric energy a year.
Nantong rubber liner Prevention of vibration and noise during installation: the prevention of vibration and noise during installation is a key point in the installation process. The prevention of vibration and noise of spiral air duct during installation is mainly from the following aspects: 1. The fan and spiral air duct are connected by hose, and the hose at the suction inlet of the fan shall be installed with appropriate tightness, Avoid noise and vibration caused by reducing the area of air inlet and outlet due to loose soft connection. 2. The spiral air duct shall be made, installed and connected with the components. The connection shall be tight to reduce the gap and avoid air leakage noise. 3 In order to prevent the spiral air duct from vibration, fixed supports shall be installed at the turning of each system spiral air duct and at the connection with the ventilator and the air outlet for shock absorption. 4 The vibration damping device shall be set according to the design requirements or construction specifications during fan installation. Air leakage rate test of spiral air duct After the installation of spiral air duct, air leakage rate test is required. According to the specifications, the air leakage rate test of spiral air duct adopts the combination of light leakage legality and quantitative air leakage rate test. The light leakage method is suitable for the tightness test of medium and low pressure systems; The air leakage rate test is suitable for sampling inspection of medium pressure system and full detection of high pressure system. Light leak detection of spiral air duct Light leak detection is a qualitative method to detect the tightness of the spiral air duct of the system by using the strong penetration of light to holes. The test method is to use a bulb with protective cover whose voltage is not higher than 36V and power is more than 100W in the spiral air duct on a certain length of spiral air duct in dark environment, and slowly move from one end of the spiral air duct to the other end. If light can be observed outside the spiral air duct during the test, it indicates that there is a leak point in the spiral air duct, and repair the leak point of the spiral air duct. rubber liner company The light leak detection method of the low-pressure system adopts the method of subsection detection and summary analysis. The spiral air duct of the tested system is not allowed to have multiple obvious light leaks in the form of slits. The spiral air duct of the low-pressure system has no more than two light leak points every 10 meters, and the average joint of 100 meters is no more than 16; For every 10 joints of spiral air duct of medium pressure system, no more than 1 light leak point, and no more than 8 joints per 100 meters are qualified.
Now on the market Nantong rubber liner There are various models of galvanized air ducts. I believe you are familiar with galvanized air ducts. Do you know the main characteristics of galvanized air ducts? If you don't know, you can have a look. It will be helpful to purchase and use galvanized air ducts in the future. Galvanized air ducts refer to air supply, exhaust and smoke exhaust ducts used in hotels, shopping malls, textiles, chemical fiber, petrochemical, machinery manufacturing, instruments, electronics, medicine, tobacco, food, medical care, storage, office buildings, subway, civil air defense, basement and other projects. Its thickness and specification can vary according to requirements. Generally, when connecting, both ends of the galvanized spiral air duct are always externally connected to the accessories. Galvanized air duct metal air duct is made of various metal materials, commonly including galvanized iron sheet and stainless steel. With the continuous development of the tank industry at present, more and more industries and enterprises have applied to the tank industry, and more and more enterprises have entered the tank industry. Composite air ducts are composed of various inorganic materials, which can be divided into various types according to their composition, but most of them are lightweight, porous, and have large thermal resistance. First of all, the galvanized air duct is exquisite, compact, durable, beautiful, noble and elegant. The support and hanger of iron sheet air duct should be in the form and specification suitable for strength and rigidity according to the national standard atlas and specifications. The supports and hangers of extra wide, overweight and other special iron sheet air ducts with diameter or side length greater than 2500 mm shall be in accordance with the design regulations. rubber liner company High quality galvanized sheet is used. Condensate water pan is molded by molding process. There are no welding seams, welding spots, and thermal insulation materials (applied to industry and buildings) that meet the fire protection standards are connected to the water pan as a whole. The galvanized air duct is small in size, and the installation of drainage pipes and lines is simple and convenient. The left and right connecting pipes and return air modes can be changed at any time to match the site conditions. Galvanized air duct can be installed in any space.
Let's take a look today Nantong rubber liner How should the maintenance work be done? Firstly, the thickness of galvanized air duct splice plate shall be within the range specified in various specifications. If it is less than the thickness, it is easy to have defects such as cracking and wrinkling due to significant increase of bending force, abnormal damage of forming roll, overload of transmission system, boring, etc. Secondly, in the dedusting system: galvanized air ducts can be used for the collection and transportation of dedusting devices. In terms of air exhaust system: there is a large amount of smoke in the dining room, dining room and hotel kitchen, which needs air exhaust. The galvanized pipe is more appropriate, with good strength, economy and practicality. In air conditioning system: galvanized air duct can be pasted with thermal insulation materials, and the surface is beautiful. In bulk material transportation: in the pneumatic conveying system, some materials with fine loose particles can be transported by galvanized pipes, which has low cost and good effect. In the ventilation system: fresh air is supplied and discharged, harmful gases are discharged outdoors, and outdoor fresh air is sent indoors. The strength of stainless steel plate is greater than that of ordinary steel plate. When stainless steel plate is used for seaming, first of all, a forming test should be carried out to avoid overloading of equipment and excessive wear or mechanical problems. Due to the poor plasticity of aluminum plate, it is easy to crack when biting into forming. Forming test shall be conducted before construction. The last point is that the protection and decoration of the galvanized layer of the galvanized air duct can be significantly improved after passivation treatment, dyeing or brushing light protective agent. and Nantong rubber liner The fire prevention function of is mainly reflected in that it is nonflammable, but it should be noted that whether the insulation layer is burned depends on the material. We recommend that galvanized air duct materials use nonflammable insulation materials such as centrifugal glass wool.