Oxygen band Price Precautions ① The acid and alkali resistant rubber hose used shall not only be oil resistant, but also be pressure resistant, heat resistant, cold resistant, wear resistant and aging resistant. ② The rubber hose should not be too long or too short, generally 1.4 meters. ③ The interface is tight and can be fastened with thin iron wire or clip to prevent falling off and air leakage. ④ It is forbidden to pull acid and alkali resistant rubber hose from one room to another or through walls, floors and floors to prevent accidents caused by rubber hose breaking and falling off. ⑤) The acid and alkali resistant rubber hose should be placed in a place where it can be seen frequently, so that it is easy to detect leakage. Check whether the rubber hose leaks after each bottle change. ⑥ Do not replace acid and alkali resistant rubber hose with universal rubber hose. Since the full rubber hose does not contain a skeleton layer, it is only necessary to use a press out machine to press out the hose; The cloth clamping hose needs to use a molding machine that wraps the adhesive tape on the inner adhesive layer; When forming the suction hose, first wrap the metal spiral wire and then wrap the inner rubber; Special fabric knitting machine or winding machine shall be used for knitting and winding hose; Knitting machine is required for knitting hose. Nanning Oxygen band The basic production processes include rubber mix processing, cord fabric and canvas processing, rubber tube molding, vulcanization, etc. The manufacturer of acid and alkali resistant rubber hose said that the processing method of the skeleton layer and the forming equipment of the rubber hose are different for different structures and different skeletons.
Nanning Oxygen band Main impact: The air volume loss of the whole system is too large to meet the air volume requirements, and the power is seriously wasted. 1. If the stainless steel welded air duct system adopts the combined flange air duct, it may be that the seam, flange strip seam and hole seam are not sealed with sealant; The allowance of segment blanking seaming is greater than the specification requirements. 2. No embedded parts are set at the joint of brick structure air duct and metal air duct, or the sealing gap is too large or the joint is not tight. Countermeasures: 1. Button type seaming can be used for medium pressure air duct; Corner seam or joint corner seam shall be used at four corners of high-pressure air duct or clean system air duct. 2. Seams of stainless steel welded air ducts, joints without flange inserts and holes must be sealed with sealing paste to prevent air leakage. 3. During construction, embedded parts shall be set at the junction of brick, structural air duct and metal air duct as required, or the civil engineering unit shall cooperate to block and seal to ensure close connection. During the air duct anti-corrosion treatment, the next anti-corrosion treatment can be carried out after the previous paint is dried; It is strictly forbidden to work without certificate. The duct type air outlet is a central air conditioning terminal air supply system that integrates the functions of air outlet, air supply pipeline, static pressure box, thermal insulation material, air valve, etc. Oxygen band Price Calculation of air duct size of stainless steel welded air duct: the equal damping method (equal pressure method) is a convenient calculation method, which is suitable for many occasions.
one Nanning Oxygen band When using, the talcum powder on the inner wall of the hose must be blown clean to prevent the channel of the welding torch from being blocked. Avoid external extrusion and mechanical damage during use, and do not fold the pipe body. 2. Care must be taken when storing and using the hose to keep it clean and free from damage. For example, avoid exposure to sunlight, rain and snow, and prevent contact with acids, alkalis, oils and other organic solvents that can damage the hose. The storage temperature shall be - 15~40 ℃, and the distance from the heat source shall not be less than 1m. 3. According to the national standards, the oxygen hose is red, the working pressure vessel is 1.5MPa, the inner diameter of the hose is 8mm, and the outer diameter is 18mm; The acetylene hose is black, the working pressure vessel is 0.3MPa, the inner diameter of the hose is 8mm, and the outer diameter is 16mm. 4. The gas cutting operation requires a large oxygen output, so the valves of the gas cylinder (or oxygen pipeline) connected to the high pressure end of the oxygen meter should be fully opened to ensure adequate flow and stable pressure. The low pressure gauge has indicated the working pressure, but the pressure drops suddenly when using oxygen. At this time, it is easy to backfire and may backfire into the oxygen hose to cause explosion. 5. Oxygen hose and acetylene hose shall not be mixed or substituted with each other, and oxygen and hose shall not be used to blow away the blockage of acetylene hose. At the same time, it is necessary to check and eliminate the defects such as gas leakage and blockage of the welding torch at any time to prevent the formation of oxygen and acetylene mixture in the hose. It should be pointed out that the hose color specified in the national standard is opposite to that specified in the international standard (ISO) (oxygen hose is black, acetylene hose is red). At the same time, it is different from the original ministerial standard (HG4-605-66) that oxygen hose is red and acetylene hose is green. Before 1966, domestic oxygen hose was black or green and acetylene hose was red. thus Oxygen band Price It causes inconsistency between the understanding and habits of the supply department and the user, and is easy to cause accidents due to the mixing and substitution of rubber hoses. At present, it should be emphasized that unified understanding and use should be carried out in accordance with the provisions of national standards, and attention should be paid to distinguishing the rubber hoses of imported equipment.
What is stainless steel spiral duct? Oxygen band Price The products are mainly used to connect the air flow between two places and play the role of ventilation. There are three types of galvanized spiral air ducts, stainless steel spiral air ducts and composite spiral air ducts. Here we mainly talk about the stainless steel spiral air duct, and briefly analyze the reason why it is widely used in villas. The so-called stainless steel air duct is strictly a kind of air duct processing technology, also known as spiral seamed thin-walled tube. The best quality is the thin-walled tube with spiral seamed made of metal strips. Because the applied material is metal, it is also called spiral seamed metal tube. It was first used in the military industry of western countries, such as ships, ship ventilation, air conditioning systems, and later used in trains Subway, mine and other civil facilities. By 2000, according to statistics, 95.6% of office buildings, shopping malls and subways in the United States had applied spiral air ducts. In civil residential buildings, 72.5% of central air conditioners use spiral air ducts. Since the mid-1990s, China has introduced this technology into the shipbuilding industry. With the rapid development of China's economy, the use of central air conditioners has increased year by year, and the quality of auxiliary products for exhaust and air supply has been continuously improved. Spiral air ducts have been widely used in some villas. (1) Product standardization: The production of spiral round air duct fittings (pipe fittings and joints) has been highly automated, systematic, and has industrialized quality control. It is well known that the wind resistance of circular duct is much smaller than that of rectangular duct. (2) Easy to install. The installation of spiral air duct significantly reduces the connection points between pipes and minimizes the leakage at the joint of pipe fittings. The typical spiral air duct is 3~6m long, while the typical rectangular air duct is only 1~1.5m long; The connection of two spiral air ducts requires only one pipe connector, while the connection of traditional rectangular air ducts often requires a completely independent double flange system. (3) Usually only small installation space is required: the same wear-resisting Oxygen band The circular pipe with a diameter of 200mm in the installation space can replace 250 × 150mm rectangular pipe. On the premise of not increasing additional installation space, several parallel circular pipes can replace flat rectangular pipes.