Ventilation pipes on ships are generally made of galvanized iron sheet production Oil resistant hose This kind of air duct is generally made by hand, and the production efficiency is low. Later, circular spiral air ducts made by machines greatly improved the production efficiency of air ducts and the quality of air ducts, which were widely used on civilian ships. However, for military ships with very strict height restrictions, circular air ducts obviously occupied more height than rectangular air ducts, which limited the promotion and use of circular spiral air ducts on ships. In the 1980s, 708 Research Institute, the Military Representative Office of Navy Garrison 426 Factory and Dalian Bohai Air Conditioning Auxiliary Factory jointly successfully trial produced the flat spiral air duct. It combines the advantages of the circular spiral air duct and the rectangular air duct. It is the third generation of air duct for ships, which is welcomed by the ship design department and has achieved good results after many ship use. The structure of the spiral air duct is the same as the round spiral air duct. It is also formed by rolling galvanized iron sheet on a special pipe coiler. Therefore, it can be produced mechanically, and the inner surface of the air duct is flat and smooth. The utilization rate of materials is also high. The thickness of galvanized iron sheet is generally 0.6mm. Although it is 0.75~slightly thinner than the commonly used rectangular air duct iron sheet, its rigidity is higher than that of rectangular air duct due to the reinforcement effect of spiral undercut. There are two types of flat spiral air duct: non adiabatic and pre adiabatic. Non adiabatic type is applicable to air conditioning ducts with simple mechanical ventilation, natural ventilation and external insulation. city in Hunan Oil resistant hose There are two types, one is air layer insulation, that is, there is 12.5~thick air layer between the inner pipe and the outer pipe. The other is that the inner and outer pipes are filled with thermal insulation materials rock wool or ultra-fine glass wool to become good thermal insulation air conditioning ducts.
city in Hunan Oil resistant hose Also called pu steel wire pipe, ventilation pipe, dust removal pipe, dust collection pipe, dust conveying pipe, industrial powder dust collection pipe, sweeping car dust collection pipe, drilling machine dust collection pipe, woodworking dust collection pipe, collectively called dust collection pipe. Therefore, industrial food dust transportation and industrial dust transportation are used for dust collection pipe. The production process structure of copper plated steel wire dust collection pipe is to wrap the pipe wall with solid elastic copper plated steel wire spirally, and the pipe wall material is coated with copper plated steel wire with special polyether PUR. PUR material is also called PU material. The thickness of pipe wall can be 0.4mm, 0.6mm, 0.9mm, 1.2mm, 1.5mm, 1.8mm and 2.1mm, depending on the customer's needs. Such as the temperature, wear resistance, flexibility and bending, hydrolysis resistance of the dust collection pipe. It is also necessary to consider whether static electricity is generated in the process of pipe full conveying dust to avoid unnecessary dust explosion and fire. Copper plated steel wire plastic coated dust collection tube is suitable for vacuum suction of powder and particle in industrial and mining, agriculture, water conservancy, civil engineering, food, petroleum, chemical industry, health and other industries, and for conveying water, oil, chemical materials, food, etc. Abrasive solids such as dust, powder, fiber, chip and particle, gas and liquid environment, for dedusting and suction plant, Oil resistant hose Where can I find it? Industrial vacuum cleaners, paper and textile fibers, are used as protective tubes. It is widely used in farmland irrigation, industry and mining, oil depot, sand extraction, sand blasting, food, medicine, indoor gas, powder, dust absorption and emission and other fields. This product is a substitute for PVC, rubber and metal pipes.
We all know Oil resistant hose Where can I find it? The noise pollution in industrial production is very serious, and noise pollution is also an important factor affecting workers' enthusiasm for production. Ball mills were once a major source of noise in mining equipment. In order to reduce the noise generated by ball mills, protect the physical and mental health of workers, improve workers' enthusiasm for production, and create greater profits for the company, Through the efforts and research of domestic and foreign industry experts, the ball mill lining plate has been transformed. Through repeated tests and comparison, it is found that the noise generated by the rubber lining plate and the manganese steel lining plate of the ball mill is far less than the manganese steel lining plate when the technical parameters are up to standard. According to the data provided by the noise monitoring station and the concentrator, We analyzed the noise intensity and the economic benefits: the domestic ND2 precision sound level meter and octave filter were used for detection, and the sound level meter was calibrated by the provincial sound level meter measurement and verification station; There is no sound insulation room in the ball mill workshop. The monitoring points are arranged according to the position of the ball mill and the flow of workers to observe the mechanical operation, 2m away from the sound source. One monitoring point is respectively set on the left and right of the east and west of the workshop and in the middle of the two ball mills. The measurement method is in accordance with the Noise Detection Specification for Industrial Enterprises. As the noise in the workshop is continuous and steady, sound level A is used as the evaluation basis. The rubber lining plate is manufactured by Hainan Rubber Lining Plate Factory according to the ball mill shell structure and the original manganese steel lining plate specification (1.4mx0.74mX0.07m). city in Hunan Oil resistant hose First, take out the manganese steel lining plate in the ball mill barrel, and then install the rubber lining plate in the barrel in turn (front and back). Each ball mill is installed with 48 pieces. First, use the pressure strip to compress, and then use the screws to fix the rubber lining plate on the ball mill barrel, so as to prevent falling off when rotating. The noise intensity of the ball mill workshop with manganese steel liner is 94-103dB (A), while the noise intensity of the ball mill workshop with rubber liner is 87-92dB (A), and the noise reduction difference is 7-11dB (A). The rubber liner has good noise reduction effect.
At present, the common air ducts in the domestic market are generally made of galvanized iron sheet, commonly known as white iron sheet. production Oil resistant hose And the thickness is 0.44~1.22mm. The thickness of iron sheet of air duct in China is generally less than 1.5mm, and the thickness of zinc coating refers to the national standard GB/T 13912-2002: 35 μ m. Average 45 μ m。 During the production of galvanized air duct, the national standard requires us to understand the following figures: 1. Appearance: conduct appearance inspection on all hot galvanized parts, and the main surface should be smooth, free of falling off, roughness and zinc spikes (if these zinc spikes will cause damage), free of peeling, missing plating, and residual solvent residue, There shall be no zinc lump and zinc ash in the parts where hot galvanized workpieces are used or where they are corrosion resistant. Note: "Roughness" and "smoothness" are relative concepts, and the coating roughness of workpiece is different from that of mechanical roller or (and) blow molding and galvanized products (such as galvanized steel plate and galvanized steel wire). As long as the coating thickness is greater than the specified value, there may be dark or light gray uneven areas on the surface of the plated parts. White rust (mainly white or gray corrosion products of alkaline zinc oxide) is allowed on the surface of galvanized workpieces stored in wet conditions. 2. Thickness: quantitative sampling shall be carried out according to the specified test method for coating thickness test. According to the size of the main surface area of hot-dip galvanized parts, the coating thickness measured in the test shall meet the following requirements: A) For parts with the main surface area greater than 2m (i.e. large parts), the average coating thickness measured on all basic measured surfaces of each part in the sample shall not be less than the minimum value of the corresponding average coating thickness: B) For parts with the main surface area less than 2m, Oil resistant hose Where can I find it? The local coating thickness measured on each basic measuring surface shall not be less than the minimum local thickness, and the average coating thickness measured on all basic measuring surfaces of the sample shall not be less than the corresponding minimum average thickness.
production Oil resistant hose The manufacturing of is highly automated and the production speed is very fast. The general air duct can produce 20~40 meters per minute. Due to the low price of its raw material galvanized strip steel compared with the whole galvanized steel sheet, and its factory production and specification standardization, the cost of spiral air duct is lower than that of rectangular air duct; In addition, the total cost of spiral air duct is low due to the less demand for supports and hangers and the less installation work. Since the four corners of rectangular air ducts are prone to turbulence, reducing the effective flow area, the spiral air ducts have good air fluidity and large effective flow area, so the secondary noise of spiral air ducts is low. Because the spiral air ducts are strong, the low-frequency noise caused by air duct vibration is smaller, the air flow performance is good, the system pressure drop is small, and the daily operation system consumes less power. Spiral air ducts in the market are generally divided into three categories according to their materials: galvanized spiral air ducts, stainless steel spiral air ducts and composite spiral air ducts. Among them, spiral air duct has the best quality and strong applicability, but its price is high. At present, the most widely circulated spiral air duct on the market is galvanized sheet. The galvanized sheet spiral air duct is basically the characteristic of stainless steel spiral air duct, but its price is only two thirds or even lower than that of spiral air duct. city in Hunan Oil resistant hose It is generally used in places where the external environment is relatively common and the requirements for air ducts are not too high. As the iron sheet is prone to chemical reaction in various environments, corrosion and rust will occur. However, zinc hardly changes in dry air. In humid air, dense basic zinc carbonate film will be formed on the surface of zinc. The spiral air duct is mainly coated with zinc on the iron sheet of the air duct to protect the iron sheet. The protective and decorative properties of zinc coating can be significantly improved after passivation treatment, dyeing or coating with light protecting agent.
You know? city in Hunan Oil resistant hose Are there reinforcement regulations and requirements? Stainless steel welded air duct is a commonly used equipment, and its reinforcement actually has regulations and requirements, do you know? If in pipe support is adopted, the spacing between each support point and the edge or flange of the air duct shall be uniform, and the value shall not be greater than 950 mm. If the corrugated bars or wires are used for reinforcement, the arrangement should be regular and the spacing should be even. Moreover, there should be no obvious deformation and other problems for the board surface. If the welded air duct is reinforced, it should be made of ribbed bars, vertical bars, angle steel, flat steel, reinforcing bars and supports inside the duct. The appropriate one can be selected according to the actual situation and needs. If angle steel or reinforcing bars are used, they should also be arranged neatly and symmetrically. The height shall not be greater than the flange width. Principles and requirements for stainless steel air duct plate connection. When the thickness is less than or equal to 1mm, the splicing of plates shall be done by biting or riveting. When the thickness of plates is greater than 1mm, argon arc welding or electric arc welding shall be used instead of gas welding. The mature argon arc welding process of "single side welding, double side forming" shall be adopted; When assembling weldments, the welding materials and process measures selected for spot welding shall be consistent with the formal Oil resistant hose Where can I find it? The requirements are the same. The misalignment deviation of the pipe butt joint is less than 20% of the wall thickness and less than 2mm. Adjust the butt joint clearance, and do not use the method of heating, tensioning and twisting the pipe. It is not allowed to strike an arc or test the current on the weldment, and the pipe surface shall be free of arc scratch and other defects. Splash prevention measures shall be taken during welding. After welding, the slag and spatter shall be cleaned with stainless steel flat shovel. After welding, the slag on the weld surface and the spatter on both sides shall be cleaned.