Nanchang Steel wire/transparent tube Main impact: The air volume loss of the whole system is too large to meet the air volume requirements, and the power is seriously wasted. 1. If the stainless steel welded air duct system adopts the combined flange air duct, it may be that the seam, flange strip seam and hole seam are not sealed with sealant; The allowance of segment blanking seaming is greater than the specification requirements. 2. No embedded parts are set at the joint of brick structure air duct and metal air duct, or the sealing gap is too large or the joint is not tight. Countermeasures: 1. Button type seaming can be used for medium pressure air duct; Corner seam or joint corner seam shall be used at four corners of high-pressure air duct or clean system air duct. 2. Seams of stainless steel welded air ducts, joints without flange inserts and holes must be sealed with sealing paste to prevent air leakage. 3. During construction, embedded parts shall be set at the junction of brick, structural air duct and metal air duct as required, or the civil engineering unit shall cooperate to block and seal to ensure close connection. During the air duct anti-corrosion treatment, the next anti-corrosion treatment can be carried out after the previous paint is dried; It is strictly forbidden to work without certificate. The duct type air outlet is a central air conditioning terminal air supply system that integrates the functions of air outlet, air supply pipeline, static pressure box, thermal insulation material, air valve, etc. Steel wire/transparent tube company Calculation of air duct size of stainless steel welded air duct: the equal damping method (equal pressure method) is a convenient calculation method, which is suitable for many occasions.
Now on the market Nanchang Steel wire/transparent tube There are various models of galvanized air ducts. I believe you are familiar with galvanized air ducts. Do you know the main characteristics of galvanized air ducts? If you don't know, you can have a look. It will be helpful to purchase and use galvanized air ducts in the future. Galvanized air ducts refer to air supply, exhaust and smoke exhaust ducts used in hotels, shopping malls, textiles, chemical fiber, petrochemical, machinery manufacturing, instruments, electronics, medicine, tobacco, food, medical treatment, storage, office buildings, subway, civil air defense, basement and other projects. Its thickness and specification can vary according to requirements. Generally, when connecting, both ends of the galvanized spiral air duct are always externally connected to the accessories. Galvanized air duct metal air duct is made of various metal materials, commonly including galvanized iron sheet and stainless steel. With the continuous development of the tank industry at present, more and more industries and enterprises have applied to the tank industry, and more and more enterprises have entered the tank industry. Composite air ducts are composed of various inorganic materials, which can be divided into various types according to their composition, but most of them are lightweight, porous, and have large thermal resistance. First of all, the galvanized air duct is exquisite, compact, durable, beautiful, noble and elegant. The support and hanger of iron sheet air duct should be in the form and specification suitable for strength and rigidity according to the national standard atlas and specifications. The supports and hangers of extra wide, overweight and other special iron sheet air ducts with diameter or side length greater than 2500 mm shall be in accordance with the design regulations. Steel wire/transparent tube company High quality galvanized sheet is used. Condensate water pan is molded by molding process. There are no welding seams, welding spots, and thermal insulation materials (applied to industry and buildings) that meet the fire protection standards are connected to the water pan as a whole. The galvanized air duct is small in size, and the installation of drainage pipes and lines is simple and convenient. The left and right connecting pipes and return air modes can be changed at any time to match the site conditions. Galvanized air duct can be installed in any space.
production Steel wire/transparent tube The inner and outer walls are smooth, the resistance of the air duct is small, the secondary noise is not generated during air supply and exhaust, the energy consumption is reduced, and the operation cost is saved. The product can be made on site, cut, drilled, and opened, the installation is simple, and the labor and time are saved. The user's investment cost is reduced, the construction period is shortened, the performance price ratio is high, and it is cheaper than other materials. After the installation is completed, no maintenance is required, and the maintenance cost is reduced. The key points of whether galvanized sheet air duct material galvanized sheet is corroded are mainly reflected in the following three aspects: ① The first corrosion of galvanized sheet in the entire service life cycle is the oxidation of the galvanized layer on the surface, resulting in white rust. After a little longer time, the white rust on the surface further reacts with carbon dioxide and other impurities in the humid air to form black spots. When the galvanized sheet is used for a long time and the galvanized layer is severely corroded, the steel base loses the sacrificial anti-corrosion effect of zinc, and begins to oxidize to generate red rust. Once the steel base begins to oxidize, the corrosion rate becomes very fast, and the life of galvanized sheet ends. ② In addition, there are two special corrosion conditions of galvanized sheet, namely, black stain. One is that after being used for a period of time, due to the influence of lead and other elements in the zinc coating, the galvanized sheet will become black in the matte part of the zinc flake. The blackened zinc coating still has a protective effect on the steel base, but has a certain impact on the service life. ③ Steel wire/transparent tube company It has excellent corrosion resistance in dry or pollution-free environment. However, in the polluted environment, the service life will be greatly shortened, so it is necessary to pre coat the film into color plates before use.
Nanchang Steel wire/transparent tube Prevention of vibration and noise during installation: the prevention of vibration and noise during installation is a key point in the installation process. The prevention of vibration and noise of spiral air duct during installation is mainly from the following aspects: 1. The fan and spiral air duct are connected by hose, and the hose at the suction inlet of the fan shall be installed with appropriate tightness, Avoid noise and vibration caused by reducing the area of air inlet and outlet due to loose soft connection. 2. The spiral air duct shall be made, installed and connected with the components. The connection shall be tight to reduce the gap and avoid air leakage noise. 3 In order to prevent the spiral air duct from vibration, fixed supports shall be installed at the turning of each system spiral air duct and at the connection with the ventilator and the air outlet for shock absorption. 4 The vibration damping device shall be set according to the design requirements or construction specifications during fan installation. Air leakage rate test of spiral air duct After the installation of spiral air duct, air leakage rate test shall be carried out. According to the specifications, the air leakage rate test of spiral air duct adopts the combination of light leakage legality and quantitative air leakage rate test. The light leakage method is suitable for the tightness test of medium and low pressure systems; The air leakage rate test is suitable for sampling inspection of medium pressure system and full detection of high pressure system. Light leak detection of spiral air duct Light leak detection is a qualitative method to detect the tightness of the spiral air duct of the system by using the strong penetration of light to holes. The test method is to use a bulb with protective cover whose voltage is not higher than 36V and power is more than 100W in the spiral air duct on a certain length of spiral air duct in dark environment, and slowly move from one end of the spiral air duct to the other end. If light can be observed outside the spiral air duct during the test, it indicates that there is a leak point in the spiral air duct, and repair the leak point of the spiral air duct. Steel wire/transparent tube company The light leak detection method of the low-pressure system adopts the method of subsection detection and summary analysis. The spiral air duct of the tested system is not allowed to have multiple obvious light leaks in the form of slits. The spiral air duct of the low-pressure system has no more than two light leak points every 10 meters, and the average joint of 100 meters is no more than 16; For every 10 joints of spiral air duct of medium pressure system, no more than 1 light leak point, and no more than 8 joints per 100 meters are qualified.