Now on the market Ningxia Steel wire/transparent tube There are various models of galvanized air ducts. I believe you are familiar with galvanized air ducts. Do you know the main characteristics of galvanized air ducts? If you don't know, you can have a look. It will be helpful to purchase and use galvanized air ducts in the future. Galvanized air ducts refer to air supply, exhaust and smoke exhaust ducts used in hotels, shopping malls, textiles, chemical fiber, petrochemical, machinery manufacturing, instruments, electronics, medicine, tobacco, food, medical treatment, storage, office buildings, subway, civil air defense, basement and other projects. Its thickness and specification can vary according to requirements. Generally, when connecting, both ends of the galvanized spiral air duct are always externally connected to the accessories. Galvanized air duct metal air duct is made of various metal materials, commonly including galvanized iron sheet and stainless steel. With the continuous development of the tank industry at present, more and more industries and enterprises have applied to the tank industry, and more and more enterprises have entered the tank industry. Composite air ducts are composed of various inorganic materials, which can be divided into various types according to their composition, but most of them are lightweight, porous, and have large thermal resistance. First of all, the galvanized air duct is exquisite, compact, durable, beautiful, noble and elegant. The support and hanger of iron sheet air duct should be in the form and specification suitable for strength and rigidity according to the national standard atlas and specifications. The supports and hangers of extra wide, overweight and other special iron sheet air ducts with diameter or side length greater than 2500 mm shall be in accordance with the design regulations. Steel wire/transparent tube company High quality galvanized sheet is used. Condensate water pan is molded by molding process. There are no welding seams, welding spots, and thermal insulation materials (applied to industry and buildings) that meet the fire protection standards are connected to the water pan as a whole. The galvanized air duct is small in size, and the installation of drainage pipes and lines is simple and convenient. The left and right connecting pipes and return air modes can be changed at any time to match the site conditions. Galvanized air duct can be installed in any space.
one Ningxia Steel wire/transparent tube When using, the talcum powder on the inner wall of the hose must be blown clean to prevent the channel of the welding torch from being blocked. Avoid external extrusion and mechanical damage during use, and do not fold the pipe body. 2. Care must be taken when storing and using the hose to keep it clean and free from damage. For example, avoid exposure to sunlight, rain and snow, and prevent contact with acids, alkalis, oils and other organic solvents that can damage the hose. The storage temperature shall be - 15~40 ℃, and the distance from the heat source shall not be less than 1m. 3. According to the national standards, the oxygen hose is red, the working pressure vessel is 1.5MPa, the inner diameter of the hose is 8mm, and the outer diameter is 18mm; The acetylene hose is black, the working pressure vessel is 0.3MPa, the inner diameter of the hose is 8mm, and the outer diameter is 16mm. 4. The gas cutting operation requires a large oxygen output, so the valves of the gas cylinder (or oxygen pipeline) connected to the high pressure end of the oxygen meter should be fully opened to ensure adequate flow and stable pressure. The low pressure gauge has indicated the working pressure, but the pressure drops suddenly when using oxygen. At this time, it is easy to backfire and may backfire into the oxygen hose to cause explosion. 5. Oxygen hose and acetylene hose shall not be mixed or substituted with each other, and oxygen and hose shall not be used to blow away the blockage of acetylene hose. At the same time, it is necessary to check and eliminate the defects such as gas leakage and blockage of the welding torch at any time to prevent the formation of oxygen and acetylene mixture in the hose. It should be pointed out that the hose color specified in the national standard is opposite to that specified in the international standard (ISO) (oxygen hose is black, acetylene hose is red). At the same time, it is different from the original ministerial standard (HG4-605-66) that oxygen hose is red and acetylene hose is green. Before 1966, domestic oxygen hose was black or green and acetylene hose was red. thus Steel wire/transparent tube company It causes inconsistency between the understanding and habits of the supply department and the user, and is easy to cause accidents due to the mixing and substitution of rubber hoses. At present, it should be emphasized that unified understanding and use should be carried out in accordance with the provisions of national standards, and attention should be paid to distinguishing the rubber hoses of imported equipment.
In the shipbuilding industry, radio industry, electrical industry, telecommunications industry, instrument industry, aviation industry, medical industry, etc., we often see acid and alkali resistant hose, then what is Ningxia Steel wire/transparent tube What about? If you want to know more, please read down! Acid and alkali resistant silicone hose is a kind of pipe specially used for power equipment, which uses acid and alkali resistant silica gel as the main raw material and tightly wraps the pipe wall with electrical grade polyethylene spiral wire. Due to the chemical inertia of acid and alkali resistant silica gel, this kind of pipe has good acid and alkali resistance performance and electrical performance, and is commonly used in the production of wires, cables and lead wires in extreme acid and alkali environments. Also called: acid and alkali resistant silicone rubber hose, acid and alkali resistant silicone rubber hose, acid and alkali resistant silicone rubber hose, acid and alkali resistant silicone rubber hose, acid and alkali resistant silicone rubber hose. Features: 1. High temperature resistance (250-300 ℃) and low temperature resistance (- 40-60 ℃); 2. Good acid and alkali resistance. Physiologically stable, able to withstand repeated harsh and disinfection conditions, resistant to ozone aging, light aging, weather aging and ultraviolet radiation. 3. Small resilience and permanent deformation (no more than 50% at 200 ℃ for 48 hours), breakdown voltage (20-25KV/mm), ozone resistance and UV resistance. Steel wire/transparent tube company Radiation resistance and other characteristics, 4. Good electrical performance, small change when exposed to moisture, water or temperature rise, even if the silica generated by short circuit combustion is still an insulator, which ensures that electrical equipment continues to work, so it is most suitable for making wires, cables and lead wires.
How to install correctly Ningxia Steel wire/transparent tube ? In the fire smoke exhaust pipe system, the airport and air valve must use non fuel, and the thickness of citizen flue and galvanized ventilation pipe should be improperly used. The high-pressure system should be selected according to the national code GB50243. When the fire smoke exhaust fan is installed on the roof, certain maintenance measures should be taken. The exposed power line must be threaded through the conduit, and the conduit material should be combined with the metal hose or Capelli and duck neck equipment to make it curved. The fire fighting system and equipment lines must be fixed with special clamps to avoid falling. Stainless steel air duct and ventilation equipment shall be made of three fabric flame retardant materials with soft connection. It is suggested that the length should be 15-30cm, and the electrical interpenetration should be completed. Bolts require the same length. The three main bodies should be grounded, ventilation equipment, and equipment and devices between dynamic loads should be equipped with shock absorption measures. When Steel wire/transparent tube company Box type pipe fittings should not be used for changing direction, variable diameter, branch road, or junction, but the wind speed of box section should not exceed 1.5m/s for air distribution and static pressure box when necessary; It is advisable to have 5-10 times the pipe diameter between conduit pipes. The length of expandable metal pipes or non-metallic soft links should not exceed 2 meters. There should be no disintegration and dead corners. During the installation process, when the length of pipe elbows and straight pipes exceeds 20 meters, add anti impact frame open room exhaust fans and add or subtract supports.