Zaozhuang Cord hose The quality is closely related to the material selection and the manufacturing process. 1. The galvanized air ducts of different specifications are made of plates of different thicknesses according to the specification requirements. On the basis of being familiar with the size and layout of air duct in the drawing, skilled technicians shall set out and cut materials to ensure that the production and installation of air duct meet relevant standards. 2. The galvanized sheet air duct flange will be made uniformly according to the series of specifications specified in the drawing. In addition, the bolt holes of the flange will be punched at a fixed distance with a punch and a mold. The forming welding of the flange will also be positioned with a special mold to ensure that the air duct flange of the same specification has interchangeability. Compared with the traditional galvanized iron pipe made by hand, the round galvanized air pipe made by mechanism has the following advantages: (1) The round galvanized air pipe has good sealing performance. (2) Both strength and rigidity are good. (3) The ventilation resistance is small, the ventilation noise is small, and the round pipe is better than the square pipe. (4) The galvanized air duct is easy to install and has few connection points. (5) Circular wear-resisting Cord hose High grade, beautiful appearance. Galvanized spiral duct is very suitable. Generally, galvanized air ducts are used, while stainless steel pipes are very suitable for galvanized spiral air ducts in corrosive and particularly humid places. Generally, galvanized air ducts are used, while stainless steel pipes are used in corrosive and particularly humid places.
The consumption of galvanized iron sheet air duct in China's chemical industry also shows a rapid growth trend. The rapid increase in the consumption of galvanized iron sheet air duct in China's chemical industry has stimulated domestic Cord hose Price With the rapid development of industry and the support of relevant government policies, in a short period of time, the production of galvanized iron air ducts in China has been developing rapidly. From the perspective of industrial chain, galvanized iron duct and upstream and downstream products enterprises of galvanized iron duct are interdependent and competing industries. Steel production enterprises can establish long-term and stable strategic alliances with downstream enterprises through deep processing of steel products, which is conducive to promoting the development of new varieties, quality improvement and market expansion of galvanized iron sheet air duct industry, and is an effective way to extend the value of steel products to the downstream and improve the competitiveness of the product market. It can be said that the development of high-quality galvanized iron duct projects has become a development strategy for Chinese galvanized iron duct manufacturers to cope with fierce market competition and improve product competitiveness. At present, in the consumption structure of galvanized iron duct in China, except for some high-end products that still rely on imports, middle and low-end products can basically achieve self-sufficiency. The situation that galvanized iron duct consumption completely depends on imports has been greatly improved, and the export volume is also expanding rapidly. However, compared with the developed areas of galvanized iron duct industry, China's galvanized iron duct industry system is not perfect, and there is still a big gap compared with Japan, South Korea and other large stainless steel reactor production countries. The development of galvanized iron sheet air duct industry in China started late, and the social demand for stainless steel reaction kettle grew too fast, which led to wear-resisting Cord hose The first problem to be solved for industrial development is to rapidly increase output to meet the growing social demand, gradually replace imports, and complete the two steps of "quantitative change" and "qualitative change". At present, the development of galvanized iron duct industry in China has completed the accumulation process of "quantitative change", and is currently facing the transformation of "quality".
wear-resisting Cord hose It will burst for a long time due to frequent and severe pressure shocks. This situation is usually not caused by excessive static pressure, but is related to the strength and frequency of pressure shock. During the operation of construction machinery, the oil pressure in the oil resistant hose will rise or fall repeatedly, and then it will form frequent pressure shocks to the oil pipe, causing the oil seal of each part to become more damaged, the oil resistant hose will bubble and break, and the pipe joint will become loose and leak. Therefore, in the process of operation, the valve rod should not be pulled too hard, and it needs to be gentle. The application temperature of the oil in the oil resistant rubber hose is too high, resulting in aging and bursting of the rubber hose. During the operation of construction machinery, the hydraulic system will cause the oil to become hot due to power failure, and the influence of external temperature (especially in summer) will cause the oil temperature to rise sharply. The higher the oiling temperature is, the easier the rubber hose ages, the worse the elasticity is, the lower the strength and sealing function are, and the oil resistant hose will burst quickly. Therefore, Cord hose Price During operation, when the temperature rise of the hydraulic system is too high or too fast, the causes should be found and eliminated in time. Necessary cooling measures shall be taken for summer operation, especially continuous operation.
Before construction, the technicians must be familiar with the drawings and relevant data carefully, and understand the technological process, working medium, pressure, temperature and other technical parameters as well as the materials, models and specifications of the materials and accessories used. The construction personnel must be fully familiar with the construction procedures, construction methods, quality standards, operating procedures and safety technical requirements, and strictly implement them during construction. Main materials used for making galvanized air duct, Zaozhuang Cord hose It shall comply with the current national product standards and the enterprise standards of the manufacturer, and shall have the factory certificate and other relevant material certificates. All material accessories must be rechecked with the design and current national product standards, and shall have the factory certificate, material quality assurance and other relevant material certificates. Combined flange air duct is also called thin-walled steel plate flange air duct. It is an air duct connected by non profile steel and made of galvanized steel plate. Its connection form can be directly pressed by strips or steel plates or the air duct and flange can be integrally formed. This kind of air duct has advanced manufacturing technology, accurate blanking, low material consumption, stable product quality, many varieties, smooth contour lines, and air leakage rate far lower than the national standard, which is conducive to the production of ventilation ducts to be industrialized, large-scale, standardized and automated. It is a scientific and technological achievement project that has been vigorously promoted in China in recent years as one of the non blue air duct processes. The National Grand Theater project is to use this new process air duct. Common plate flange air duct 1 Fabrication of composite flange air duct Common mechanical equipment for fabrication of composite flange air duct include: rectangular air duct full-automatic production line, plasma automatic cutting machine, flange strip forming machine, hook code forming machine, conjoined flange forming machine, etc. The combined flange air duct is based on the air duct size given in the drawing, Cord hose Price Fully automatic production line is used to produce coiled material with a common width of 1250mm, and the plate thickness is 0.5~1.2mm. When the large side of the air duct is less than or equal to 2m, the air duct is formed into TDC1 flange, and the standard pipe length is 1170mm; When the large side of the fabricated air duct is less than or equal to 2.5m, the air duct is formed into TDC2 flange, and the standard pipe length is 1250mm; When the large side of the fabricated air duct is more than 2.5m, the air duct is formed into an angle steel flange, and the standard pipe length is 1230mm