Mount Huangshan Acetylene tape Compared with rectangular duct, it is widely used in the ventilation industry. Why? Let's start with its advantages to solve this problem and make it clear. At the same time, through the following introduction, I hope you can know more about the spiral duct and make yourself more professional in this regard. Now let's understand the function of air duct: function 1: air supply and ventilation. It is used to transport fresh air and waste gas, exhaust harmful gas, and deliver outdoor fresh air to the room. Generally speaking, spiral air duct is good. If the environment is humid or corrosive, stainless steel shall be used to avoid rust and corrosion of air duct. Function 2: provide cold air. It is mainly used for central air conditioning, but thermal insulation materials need to be added on the air duct. Function 3: Exhaust lampblack: It is mainly used to exhaust kitchen lampblack in restaurants, hotels and other places. Generally, circular air ducts are used. Function 4: dedusting and bulk material conveying: in the factory workshop, the air duct is used for dedusting, and the spiral air duct can be used for conveying particles, such as foam plastic particles, because Acetylene tape Where can I find it? The proportion of products is small. 1) Under the same plate thickness and pipe diameter, the strength of spiral air duct is higher. (2) Under the same section, the structural tension of spiral air duct is more reasonable, the stiffness is better, and the noise and vibration can be greatly reduced. (3) At the same length, the number of flange connections of spiral air duct is less, which can greatly improve the ventilation quality of the system.
How to install correctly Mount Huangshan Acetylene tape ? In the fire smoke exhaust pipe system, the airport and air valve must use non fuel, and the thickness of citizen flue and galvanized ventilation pipe should be improperly used. The high-pressure system should be selected according to the national code GB50243. When the fire smoke exhaust fan is installed on the roof, certain maintenance measures should be taken. The exposed power line must be threaded through the conduit, and the conduit material should be combined with the metal hose or Capelli and duck neck equipment to make it curved. The fire fighting system and equipment lines must be fixed with special clamps to avoid falling. Stainless steel air duct and ventilation equipment shall be made of three fabric flame retardant materials with soft connection. It is suggested that the length should be 15-30cm, and the electrical interpenetration should be completed. Bolts require the same length. The three main bodies should be grounded, ventilation equipment, and equipment and devices between dynamic loads should be equipped with shock absorption measures. When Acetylene tape Where can I find it? Box type pipe fittings should not be used for changing direction, variable diameter, branch road, or junction, but the wind speed of box section should not exceed 1.5m/s for air distribution and static pressure box when necessary; It is advisable to have 5-10 times the pipe diameter between conduit pipes. The length of expandable metal pipes or non-metallic soft links should not exceed 2 meters. There should be no disintegration and dead corners. During the installation process, when the length of pipe elbows and straight pipes exceeds 20 meters, add anti impact frame open room exhaust fans and add or subtract supports.
The development trend of HVAC duct is high quality Acetylene tape Now more and more companies choose advanced spiral duct technology. The advantages of spiral air duct are as follows: 1. Good air tightness. Spiral air duct greatly reduces the connection of air duct and minimizes the leakage between connectors. The typical spiral air duct is 3-6m, but the typical rectangular air duct is only 1-1.5m; At the same time, only one connector is required to connect two spiral air ducts, while a typical rectangular air duct connector requires separate double flanges. 2. Standardized products. The production of spare parts (pipes and connectors) is highly automated and systematic, and has industrialized quality control. 3. Low installation cost. The installation of round duct only needs one third of that of rectangular duct. 4. Save space. Under the same pressure and the same installation space, the spiral air duct with a diameter of 200mm can replace the rectangular air duct with a diameter of 250x150mm. Without increasing the installation space, multiple spiral pipes can be used instead of wider rectangular pipes. Considering various factors, in most cases, spiral pipes require less space than rectangular pipes. Under the same pressure, the installation space of several spiral pipes is equal to or less than that of rectangular pipes. Most rectangular pipe systems require 4 bolts to fix, which will increase 40~80mm in each direction. 5. The pressure drop is low. As we know, spiral duct has lower ventilation resistance than rectangular duct. 6. Precision locking technology. Mount Huangshan Acetylene tape The mold on the is made of special steel. After years of use, the surface remains unchanged, making the surface of the spiral air duct free of scratches and extending the service life. 7. The perimeter of rectangular air duct with length width ratio of 1:3 at the same section is 40% larger than that of spiral air duct, which means that spiral air duct saves more materials and reduces thermal insulation.
Air duct mainly refers to the ventilation duct of the central air-conditioning system, which is often ignored, but it is an important part of the air-conditioning system. Mount Huangshan Acetylene tape What are the regulations for welding air ducts? Gongfa HVAC is a manufacturer dedicated to the production of air ducts, which has been recognized and supported by the majority of users for many years. 1、 The welding regulations of carbon steel plate air duct are as follows: 1. The carbon steel plate air duct should be welded by DC welder. Introduction to welding air duct If AC welding machine is used for welding, a vibrator must be added to reduce excitation and stabilize the arc. When welding steel plates, the arc is unstable, which can lead to deterioration of weld quality. 2. Before welding, remove the dirt, oil stain and rust at the welding port; When spot welding or continuous welding is used, the oxide shall also be removed. The butt joint shall be kept with the minimum gap, and the overlap at the manual spot welding location shall be removed in time. After welding, the electrode slag and residual welding wire in the weld and its surrounding area shall be removed in time. 2、 The welding regulations of stainless steel air duct are as follows: 1. Before welding the air duct, remove the grease and dirt in the weld area to prevent pores and sand holes in the weld. Cleaning can be carried out with gasoline, acetone, etc. When welding stainless steel plates by electric arc welding, the surfaces on both sides of the weld should be coated with white ash, Mount Huangshan Acetylene tape To avoid welding slag splashes adhering to the surface of the plate. 2. After welding, attention shall be paid to removing the slag at the weld, brushing the metal luster with a copper wire brush, pickling with 10% nitric acid solution, and then cleaning with hot water.
At present, the common air ducts in the domestic market are generally made of galvanized iron sheet, commonly known as white iron sheet. high quality Acetylene tape And the thickness is 0.44~1.22mm. The thickness of iron sheet of air duct in China is generally less than 1.5mm, and the thickness of zinc coating refers to the national standard GB/T 13912-2002: 35 μ m. Average 45 μ m。 During the production of galvanized air duct, the national standard requires us to understand the following figures: 1. Appearance: conduct appearance inspection on all hot galvanized parts, and the main surface should be smooth, free of falling off, roughness and zinc spikes (if these zinc spikes will cause damage), free of peeling, missing plating, and residual solvent residue, There shall be no zinc lump and zinc ash in the parts where hot galvanized workpieces are used or where they are corrosion resistant. Note: "Roughness" and "smoothness" are relative concepts, and the coating roughness of workpiece is different from that of mechanical roller or (and) blow molding and galvanized products (such as galvanized steel plate and galvanized steel wire). As long as the coating thickness is greater than the specified value, there may be dark or light gray uneven areas on the surface of the plated parts. White rust (mainly white or gray corrosion products of alkaline zinc oxide) is allowed on the surface of galvanized workpieces stored in wet conditions. 2. Thickness: quantitative sampling shall be carried out according to the specified test method for coating thickness test. According to the size of the main surface area of hot-dip galvanized parts, the coating thickness measured in the test shall meet the following requirements: A) For parts with the main surface area greater than 2m (i.e. large parts), the average coating thickness measured on all basic measured surfaces of each part in the sample shall not be less than the minimum value of the corresponding average coating thickness: B) For parts with the main surface area less than 2m, Acetylene tape Where can I find it? The local coating thickness measured on each basic measuring surface shall not be less than the minimum local thickness, and the average coating thickness measured on all basic measuring surfaces of the sample shall not be less than the corresponding minimum average thickness.