Huanggang Acetylene pipe Compared with rectangular duct, it is widely used in the ventilation industry. Why? Let's start with its advantages to solve this problem and make it clear. At the same time, through the following introduction, I hope you can know more about the spiral duct and make yourself more professional in this regard. Now let's understand the function of air duct: function 1: air supply and ventilation. It is used to transport fresh air and waste gas, exhaust harmful gas, and deliver outdoor fresh air to the room. Generally speaking, spiral air duct is good. If the environment is humid or corrosive, stainless steel shall be used to avoid rust and corrosion of air duct. Function 2: provide cold air. It is mainly used for central air conditioning, but thermal insulation materials need to be added on the air duct. Function 3: Exhaust lampblack: It is mainly used to exhaust kitchen lampblack in restaurants, hotels and other places. Generally, circular air ducts are used. Function 4: dedusting and bulk material conveying: in the factory workshop, the air duct is used for dedusting, and the spiral air duct can be used for conveying particles, such as foam plastic particles, because Acetylene pipe company The proportion of products is small. 1) Under the same plate thickness and pipe diameter, the strength of spiral air duct is higher. (2) Under the same section, the structural tension of spiral air duct is more reasonable, the stiffness is better, and the noise and vibration can be greatly reduced. (3) At the same length, the number of flange connections of spiral air duct is less, which can greatly improve the ventilation quality of the system.
Huanggang Acetylene pipe The structure is composed of liquid resistant synthetic rubber inner rubber layer, medium rubber layer, I or II or III steel wire braid reinforcement layer, and weather resistant synthetic rubber outer rubber layer. Sand pumping hose features: 1. Sand pumping hose is made of special synthetic rubber, which has excellent oil resistance, heat resistance and aging resistance. 2. The rubber hose has high bearing pressure and excellent pulse performance. 3. The pipe body is tightly combined, soft to use, and has little deformation under pressure. 4. Sand pumping hose has excellent bending resistance and fatigue resistance. 5. The sand pumping hose is long, φ 20 meters above 32, φ Below 25 meters, it can reach 10 meters or even 100 meters. Sand pumping hose parameters: 1. The inner wall of nylon cord hose is smooth and has little friction. Reinforcing layer: high-strength synthetic wire, spiral winding of steel wire and iron wire (sand suction pipe) 2 wear-resisting Acetylene pipe Flange connection (ANSI150 standard flange) 3. Nominal pressure: 20BAR4, temperature: - 50 ℃ -+95 ℃ 5. Working pressure of sand suction hose and mud discharge pipe: positive pressure: 10kg; Test pressure: working negative pressure of 15kg steel ring sand suction hose: ≥ 15kg sand suction hose has strong flexibility, which is mainly used as the sand pump sand discharge pipe to connect the sand transport pipe and sand pump, as well as the pipe connection bend.
How to install correctly Huanggang Acetylene pipe ? In the fire smoke exhaust pipe system, the airport and air valve must use non fuel, and the thickness of citizen flue and galvanized ventilation pipe should be improperly used. The high-pressure system should be selected according to the national code GB50243. When the fire smoke exhaust fan is installed on the roof, certain maintenance measures should be taken. The exposed power line must be threaded through the conduit, and the conduit material should be combined with the metal hose or Capelli and duck neck equipment to make it curved. The fire fighting system and equipment lines must be fixed with special clamps to avoid falling. Stainless steel air duct and ventilation equipment shall be made of three fabric flame retardant materials with soft connection. It is suggested that the length should be 15-30cm, and the electrical interpenetration should be completed. Bolts require the same length. The three main bodies should be grounded, ventilation equipment, and equipment and devices between dynamic loads should be equipped with shock absorption measures. When Acetylene pipe company Box type pipe fittings should not be used for changing direction, variable diameter, branch road, or junction, but the wind speed of box section should not exceed 1.5m/s for air distribution and static pressure box when necessary; It is advisable to have 5-10 times the pipe diameter between conduit pipes. The length of expandable metal pipes or non-metallic soft links should not exceed 2 meters. There should be no disintegration and dead corners. During the installation process, when the length of pipe elbows and straight pipes exceeds 20 meters, add anti impact frame open room exhaust fans and add or subtract supports.
Acetylene pipe company It has become the standard configuration of the modern new ball mill, but many problems may occur during the use or installation of the rubber lining plate, which will cause the failure of the rubber lining plate of the ball mill. Here is a brief introduction to the causes of the more common failure of the rubber lining plate of the ball mill. The design and installation are not professional and reasonable. The design and installation are also common problems for many novice manufacturers. For example, the bolt holes for fixing the ball mill lining plate are square, which will cause stress concentration and fracture. Adjust the size of lining plate to control the gap between lining plates at about 8mm; The installation quality of lining plate is very important to the safe operation of ball mill. First, tighten the fixed wedge symmetrically, put the lining plate in sequence, and then use the tightening wedge to secure it; Therefore, professional installation guidance can easily avoid these problems. The reason why the rubber lining plate of the ball mill does not match the steel ball is relatively common, and it is easy for many novice manufacturers to ignore and make mistakes. During the operation of the ball mill, the rubber lining plate of the ball mill, materials and steel balls promote the normal grinding and crushing of the ball mill due to the interaction of forces. The hardness of materials is related to wear resistance, and the wear resistance increases with the increase of hardness, Huanggang Acetylene pipe It is a pair of friction pairs, and the increase of hardness of one side will cause the wear of the other side to increase. Therefore, the high wear-resistant rubber lining plate is matched with the high wear-resistant steel ball, and the low wear-resistant rubber lining plate is matched with the low wear-resistant steel ball, so as to ensure the normal wear of the rubber lining plate of the ball mill and extend the service life of the ball mill.
The development trend of HVAC duct is wear-resisting Acetylene pipe Now more and more companies choose advanced spiral duct technology. The advantages of spiral air duct are as follows: 1. Good air tightness. Spiral air duct greatly reduces the connection of air duct and minimizes the leakage between connectors. The typical spiral air duct is 3-6m, but the typical rectangular air duct is only 1-1.5m; At the same time, only one connector is required to connect two spiral air ducts, while a typical rectangular air duct connector requires separate double flanges. 2. Standardized products. The production of spare parts (pipes and connectors) is highly automated and systematic, and has industrialized quality control. 3. Low installation cost. The installation of round duct only needs one third of that of rectangular duct. 4. Save space. Under the same pressure and the same installation space, the spiral air duct with a diameter of 200mm can replace the rectangular air duct with a diameter of 250x150mm. Without increasing the installation space, multiple spiral pipes can be used instead of wider rectangular pipes. Considering various factors, in most cases, spiral pipes require less space than rectangular pipes. Under the same pressure, the installation space of several spiral pipes is equal to or less than that of rectangular pipes. Most rectangular pipe systems require 4 bolts to fix, which will increase 40~80mm in each direction. 5. The pressure drop is low. As we know, spiral duct has lower ventilation resistance than rectangular duct. 6. Precision locking technology. Huanggang Acetylene pipe The mold on the is made of special steel. After years of use, the surface remains unchanged, making the surface of the spiral air duct free of scratches and extending the service life. 7. The perimeter of rectangular air duct with length width ratio of 1:3 at the same section is 40% larger than that of spiral air duct, which means that spiral air duct saves more materials and reduces thermal insulation.