You know? Xining Braided hose Are there reinforcement regulations and requirements? Stainless steel welded air duct is a commonly used equipment, and its reinforcement actually has regulations and requirements, do you know? If in pipe support is adopted, the spacing between each support point and the edge or flange of the air duct shall be uniform, and the value shall not be greater than 950 mm. If the corrugated bars or wires are used for reinforcement, the arrangement should be regular and the spacing should be even. Moreover, there should be no obvious deformation and other problems for the board surface. If the welded air duct is reinforced, it should be made of ribbed bars, vertical bars, angle steel, flat steel, reinforcing bars and supports inside the duct. The appropriate one can be selected according to the actual situation and needs. If angle steel or reinforcing bars are used, they should also be arranged neatly and symmetrically. The height shall not be greater than the flange width. Principles and requirements for stainless steel air duct plate connection. When the thickness is less than or equal to 1mm, the splicing of plates shall be done by biting or riveting. When the thickness of plates is greater than 1mm, argon arc welding or electric arc welding shall be used instead of gas welding. The mature argon arc welding process of "single side welding, double side forming" shall be adopted; When assembling weldments, the welding materials and process measures selected for spot welding shall be consistent with the formal Braided hose Price The requirements are the same. The misalignment deviation of the pipe butt joint is less than 20% of the wall thickness and less than 2mm. Adjust the butt joint clearance, and do not use the method of heating, tensioning and twisting the pipe. It is not allowed to strike an arc or test the current on the weldment, and the pipe surface shall be free of arc scratch and other defects. Splash prevention measures shall be taken during welding. After welding, the slag and spatter shall be cleaned with stainless steel flat shovel. After welding, the slag on the weld surface and the spatter on both sides shall be cleaned.
Xining Braided hose Prevention of vibration and noise during installation: the prevention of vibration and noise during installation is a key point in the installation process. The prevention of vibration and noise of spiral air duct during installation is mainly from the following aspects: 1. The fan and spiral air duct are connected by hose, and the hose at the suction inlet of the fan shall be installed with appropriate tightness, Avoid noise and vibration caused by reducing the area of air inlet and outlet due to loose soft connection. 2. The spiral air duct shall be made, installed and connected with the components. The connection shall be tight to reduce the gap and avoid air leakage noise. 3 In order to prevent the spiral air duct from vibration, fixed supports shall be installed at the turning of each system spiral air duct and at the connection with the ventilator and the air outlet for shock absorption. 4 The vibration damping device shall be set according to the design requirements or construction specifications during fan installation. Air leakage rate test of spiral air duct After the installation of spiral air duct, air leakage rate test is required. According to the specifications, the air leakage rate test of spiral air duct adopts the combination of light leakage legality and quantitative air leakage rate test. The light leakage method is suitable for the tightness test of medium and low pressure systems; The air leakage rate test is suitable for sampling inspection of medium pressure system and full detection of high pressure system. Light leak detection of spiral air duct Light leak detection is a qualitative method to detect the tightness of the spiral air duct of the system by using the strong penetration of light to holes. The test method is to use a bulb with protective cover whose voltage is not higher than 36V and power is more than 100W in the spiral air duct on a certain length of spiral air duct in dark environment, and slowly move from one end of the spiral air duct to the other end. If light can be observed outside the spiral air duct during the test, it indicates that there is a leak point in the spiral air duct, and repair the leak point of the spiral air duct. Braided hose Price The light leak detection method of the low-pressure system adopts the method of subsection detection and summary analysis. The spiral air duct of the tested system is not allowed to have multiple obvious light leaks in the form of slits. The spiral air duct of the low-pressure system has no more than two light leak points every 10 meters, and the average joint of 100 meters is no more than 16; For every 10 joints of spiral air duct of medium pressure system, no more than 1 light leak point, and no more than 8 joints per 100 meters are qualified.
Xining Braided hose 1. The manufacturing quality shall be guaranteed according to the national standards of Oxygen Hose (GB/T2550-91) and Acetylene Hose (GB/T2551-91) respectively, and the hose shall have sufficient compressive strength and flame retardant characteristics. According to the national standard, the oxygen hose is red, the working pressure vessel is 1.5MPa, the inner diameter of the hose is 8mm, and the outer diameter is 18mm; 2. Care must be taken when storing and using the hose to keep it clean and free from damage. For example, avoid exposure to sunlight, rain and snow, and prevent contact with substances such as acid, alkali, oil and other organic solvents that can damage the hose. The storage temperature shall be - 15 ℃~40 ℃, and the distance from the personnel shall not be less than 1m; 3. When using a new hose, the talcum powder on the inner wall of the hose must be blown out first to prevent the channel of the welding torch from being blocked. Avoid external extrusion and mechanical damage during use, and do not fold the pipe body. 4. If the oxygen hose catches fire, stop the air supply first, and then deal with the fire hose, but do not bend the hose. The cylinder valve must be closed when the cylinder is not in use or after work. 5. The hose with bulge, crack or air leakage shall not be used, and the air leakage hose shall not be used after being stuck with adhesive tape. Braided hose Price When connecting the two ends of the hose with tools, clamp or wire shall be used to fasten, and the intermediate joint shall be fastened with a gas pipe connector.
Many people don't know much about spiral tube. In fact wear-resisting Braided hose It is very extensive. Spiral air duct is mainly used to connect the two places for ventilation. Spiral air ducts (stainless steel and galvanized iron sheet) are widely used in the market. Spiral air duct market is generally divided into three categories according to material: galvanized spiral air duct, stainless steel spiral air duct and composite spiral air duct. Among them, the stainless steel air duct has good quality and strong applicability, but its price is high. The return air duct of purification system, central air conditioning ventilation duct, industrial air supply and exhaust duct, environmental protection system suction and exhaust duct, mine gas drainage duct, mine coating duct, etc. The spiral duct is first used for ventilation and cooling, which belongs to the category of air duct. It is named according to its purpose, but it can also be used in other places, even for drainage, drainage or as a container, which cannot be called a pipe. Named according to the structure, it should be called spiral grooved thin-walled tube, because it is mainly made of metal, also called spiral grooved metal tube. According to the material name, there may be several names: galvanized (any zinc) (galvanized) (iron), spiral pipe, stainless steel spiral pipe (stainless steel acid resistant steel), aluminum (aluminum) spiral pipe, or in order to distinguish from the existing acid resistant stainless steel pipe, Braided hose Price It can be called ultra-thin stainless steel pipe, because it can use 0.3mm or even thinner to roll stainless steel strip.