Lhasa Steel wire/transparent tube Main impact: The air volume loss of the whole system is too large to meet the air volume requirements, and the power is seriously wasted. 1. If the stainless steel welded air duct system adopts the combined flange air duct, it may be that the seam, flange strip seam and hole seam are not sealed with sealant; The allowance of segment blanking seaming is greater than the specification requirements. 2. No embedded parts are set at the joint of brick structure air duct and metal air duct, or the sealing gap is too large or the joint is not tight. Countermeasures: 1. Button type seaming can be used for medium pressure air duct; Corner seam or joint corner seam shall be used at four corners of high-pressure air duct or clean system air duct. 2. Seams of stainless steel welded air ducts, joints without flange inserts and holes must be sealed with sealing paste to prevent air leakage. 3. During construction, embedded parts shall be set at the junction of brick, structural air duct and metal air duct as required, or the civil engineering unit shall cooperate to block and seal to ensure close connection. During the air duct anti-corrosion treatment, the next anti-corrosion treatment can be carried out after the previous paint is dried; It is strictly forbidden to work without certificate. The duct type air outlet is a central air conditioning terminal air supply system that integrates the functions of air outlet, air supply pipeline, static pressure box, thermal insulation material, air valve, etc. Steel wire/transparent tube Price Calculation of air duct size of stainless steel welded air duct: the equal damping method (equal pressure method) is a convenient calculation method, which is suitable for many occasions.
The air conditioning in the hall of a giant building is provided by the 6FWB unit fixed in the basement. wear-resisting Steel wire/transparent tube The vibration of the unit is transmitted to the ground hall through the bridge connecting the sand blasting hose pipe, and the noise value reaches 45dB. In such an environment, people always feel uncomfortable. After the improved design, sandblasting rubber pipes were connected in series on the connecting pipes, which not only absorbed some of the noise generated by the unit vibration, but also the noise generated by the fluid pulsation in the pipeline system. At this time, the noise value in the ground hall was only 33dB, greatly improving the environment in the hall. The movable cylinder on the vulcanizing press will move upward and downward for the need of loading and unloading the mold. After repeated reciprocating movements, the copper serpentine will suffer from fatigue fracture. Although it can still be used after repair, it will cause time loss if it is stopped for repair. Steel wire/transparent tube Price Although it has good soft properties and strong fatigue resistance, it is weak in pressure bearing, temperature resistance, aging resistance and other aspects, and can not continue after several months of use. The good comprehensive performance of sand blasting hose is fully reflected here. In the general industrial field, in addition to pressure and temperature, there are often severe conditions such as fatigue, corrosion, vibration, compression, impact, etc. Under such circumstances, it is most appropriate to use sandblasting hose to compensate for the position movement of the pipeline.
We all know Steel wire/transparent tube Price The noise pollution in industrial production is very serious, and noise pollution is also an important factor affecting workers' enthusiasm for production. Ball mills were once a major source of noise in mining equipment. In order to reduce the noise generated by ball mills, protect the physical and mental health of workers, improve workers' enthusiasm for production, and create greater profits for the company, Through the efforts and research of domestic and foreign industry experts, the ball mill liner has been transformed. Through repeated tests and comparison, it is found that the noise generated by the rubber liner and the manganese steel liner of the ball mill is far less than the manganese steel liner when the technical parameters are up to standard. According to the data provided by the noise monitoring station and the concentrator, We analyzed the noise intensity and the economic benefits: the domestic ND2 precision sound level meter and octave filter were used for detection, and the sound level meter was calibrated by the provincial sound level meter measurement and verification station; There is no sound insulation room in the ball mill workshop. The monitoring points are arranged according to the position of the ball mill and the flow of workers to observe the mechanical operation, 2m away from the sound source. One monitoring point is respectively set on the left and right of the east and west of the workshop and in the middle of the two ball mills. The measurement method is in accordance with the Noise Detection Specification for Industrial Enterprises. As the noise in the workshop is continuous and steady, sound level A is used as the evaluation basis. The rubber lining plate is manufactured by Hainan Rubber Lining Plate Factory according to the ball mill shell structure and the original manganese steel lining plate specification (1.4mx0.74mX0.07m). Lhasa Steel wire/transparent tube First, take out the manganese steel lining plate in the ball mill barrel, and then install the rubber lining plate in the barrel in turn (front and back). Each ball mill is installed with 48 pieces. First, use the pressure strip to compress, and then use the screws to fix the rubber lining plate on the ball mill barrel, so as to prevent falling off when rotating. The noise intensity of the ball mill workshop with manganese steel liner is 94-103dB (A), while the noise intensity of the ball mill workshop with rubber liner is 87-92dB (A), and the noise reduction difference is 7-11dB (A). The rubber liner has good noise reduction effect.
What is stainless steel spiral duct? Steel wire/transparent tube Price The products are mainly used to connect the air flow between two places and play the role of ventilation. There are three types of galvanized spiral air ducts, stainless steel spiral air ducts and composite spiral air ducts. Here we mainly talk about the stainless steel spiral air duct, and briefly analyze the reason why it is widely used in villas. The so-called stainless steel air duct is strictly a kind of air duct processing technology, also known as spiral seamed thin-walled tube. The best quality is the thin-walled tube with spiral seamed made of metal strips. Because the applied material is metal, it is also called spiral seamed metal tube. It was first used in the military industry of western countries, such as ships, ship ventilation, air conditioning systems, and later used in trains Subway, mine and other civil facilities. By 2000, according to statistics, 95.6% of office buildings, shopping malls and subways in the United States had applied spiral air ducts. In civil residential buildings, 72.5% of central air conditioners use spiral air ducts. Since the mid-1990s, China has introduced this technology into the shipbuilding industry. With the rapid development of China's economy, the use of central air conditioners has increased year by year, and the quality of auxiliary products for exhaust and air supply has been continuously improved. Spiral air ducts have been widely used in some villas. (1) Product standardization: The production of spiral round air duct fittings (pipe fittings and joints) has been highly automated, systematic, and has industrialized quality control. It is well known that the wind resistance of circular duct is much smaller than that of rectangular duct. (2) Easy to install. The installation of spiral air duct significantly reduces the connection points between pipes and minimizes the leakage at the joint of pipe fittings. The typical spiral air duct is 3~6m long, while the typical rectangular air duct is only 1~1.5m long; The connection of two spiral air ducts requires only one pipe connector, while the connection of traditional rectangular air ducts often requires a completely independent double flange system. (3) Usually only small installation space is required: the same wear-resisting Steel wire/transparent tube The circular pipe with a diameter of 200mm in the installation space can replace 250 × 150mm rectangular pipe. On the premise of not increasing additional installation space, several parallel circular pipes can replace flat rectangular pipes.