Linyi Braided hose Compared with rectangular duct, it is widely used in the ventilation industry. Why? Let's start with its advantages to solve this problem and make it clear. At the same time, through the following introduction, I hope you can know more about the spiral duct and make yourself more professional in this regard. Now let's understand the function of air duct: function 1: air supply and ventilation. It is used to transport fresh air and waste gas, exhaust harmful gas, and deliver outdoor fresh air to the room. Generally speaking, spiral air duct is good. If the environment is humid or corrosive, stainless steel shall be used to avoid rust and corrosion of air duct. Function 2: provide cold air. It is mainly used for central air conditioning, but thermal insulation materials need to be added on the air duct. Function 3: Exhaust lampblack: It is mainly used to exhaust kitchen lampblack in restaurants, hotels and other places. Generally, circular air ducts are used. Function 4: dedusting and bulk material conveying: in the factory workshop, the air duct is used for dedusting, and the spiral air duct can be used for conveying particles, such as foam plastic particles, because Braided hose company The proportion of products is small. 1) Under the same plate thickness and pipe diameter, the strength of spiral air duct is higher. (2) Under the same section, the structural tension of spiral air duct is more reasonable, the stiffness is better, and the noise and vibration can be greatly reduced. (3) At the same length, the number of flange connections of spiral air duct is less, which can greatly improve the ventilation quality of the system.
Linyi Braided hose The quality is closely related to the material selection and the manufacturing process. 1. The galvanized air ducts of different specifications are made of plates of different thicknesses according to the specification requirements. On the basis of being familiar with the size and layout of the air duct in the drawing, skilled technicians will set out and cut the material to ensure that the air duct production and installation meet the relevant standards. 2. The galvanized sheet air duct flange will be made uniformly according to the series of specifications specified in the drawing. In addition, the bolt holes of the flange will be punched at a fixed distance with a punch and a mold. The forming welding of the flange will also be positioned with a special mold to ensure that the air duct flange of the same specification has interchangeability. Compared with the traditional galvanized iron pipe made by hand, the round galvanized air pipe made by mechanism has the following advantages: (1) The round galvanized air pipe has good sealing performance. (2) Both strength and rigidity are good. (3) The ventilation resistance is small, the ventilation noise is small, and the round pipe is better than the square pipe. (4) The galvanized air duct is easy to install and has few connection points. (5) Circular production Braided hose High grade, beautiful appearance. Galvanized spiral duct is very suitable. Generally, galvanized air ducts are used, while stainless steel pipes are very suitable for galvanized spiral air ducts in corrosive and particularly humid places. Generally, galvanized air ducts are used, while stainless steel pipes are used in corrosive and particularly humid places.
“ production Braided hose What are the applications in engineering transformation? " In this issue, we will explain this problem for you. Those who have consulted this problem will come to see it: First, we should consider the water supply and drainage of all water related equipment, such as wells, pumps, etc., their location, installation method and temperature, including galvanized air ducts. 2、 It is very important to consider galvanized air duct in advance to avoid temporary replacement of galvanized air duct materials. 3、 After the location of the machine tool is determined, the drainage outlet can be considered to be arranged underground, which is not only convenient but also durable. 4、 After river reconstruction, there should be a suppression test, but now many construction teams do not suppress the test. It is usually said that it is not important, that there is water and pressure in the galvanized air duct, and so on. Try to be present to suppress the test. 5. If the installation is completed, pay attention to the inspection of the workshop, water pump room and FRPP drain. If the drainage system is slow, the installation program should be able to open the installation. Water outlets should be protected, especially during civil engineering construction, Braided hose company It may cause soil loss and blockage. I believe that you have a better understanding of this information, and we will continue to improve the galvanized air duct to make it more widely used.
Before construction, the technicians must be familiar with the drawings and relevant data carefully, and understand the technological process, working medium, pressure, temperature and other technical parameters as well as the materials, models and specifications of the materials and accessories used. The construction personnel must be fully familiar with the construction procedures, construction methods, quality standards, operating procedures and safety technical requirements, and strictly implement them during construction. Main materials used for making galvanized air duct, Linyi Braided hose It shall comply with the current national product standards and the enterprise standards of the manufacturer, and shall have the factory certificate and other relevant material certificates. All material accessories must be rechecked with the design and current national product standards, and shall have the factory certificate, material quality assurance and other relevant material certificates. Combined flange air duct is also called thin-walled steel plate flange air duct. It is an air duct connected by non profile steel and made of galvanized steel plate. Its connection form can be directly pressed by strips or steel plates or the air duct and flange can be integrally formed. This kind of air duct has advanced manufacturing technology, accurate blanking, low material consumption, stable product quality, many varieties, smooth contour lines, and air leakage rate far lower than the national standard, which is conducive to the production of ventilation ducts to be industrialized, large-scale, standardized and automated. It is a scientific and technological achievement project that has been vigorously promoted in China in recent years as one of the non blue air duct processes. The National Grand Theater project is to use this new process air duct. Common plate flange air duct 1 Fabrication of composite flange air duct Common mechanical equipment for fabrication of composite flange air duct include: rectangular air duct full-automatic production line, plasma automatic cutting machine, flange strip forming machine, hook code forming machine, conjoined flange forming machine, etc. The combined flange air duct is based on the air duct size given in the drawing, Braided hose company Fully automatic production line is used to produce coiled material with a common width of 1250mm, and the plate thickness is 0.5~1.2mm. When the large side of the air duct is less than or equal to 2m, the air duct is formed into TDC1 flange, and the standard pipe length is 1170mm; When the large side of the fabricated air duct is less than or equal to 2.5m, the air duct is formed into TDC2 flange, and the standard pipe length is 1250mm; When the large side of the fabricated air duct is more than 2.5m, the air duct is formed into an angle steel flange, and the standard pipe length is 1230mm
1. Mutual wear of rubber lining plate and steel ball of ball mill: both the rubber lining plate and steel ball of ball mill are vulnerable parts. During grinding, the steel ball and material of ball mill do throw line falling movement in the barrel Linyi Braided hose It will collide with steel balls and materials and cause friction. In continuous operation, the rubber lining plate and steel ball of ball mill will be severely worn, which is directly related to the hardness of materials. The greater the hardness of the material, the faster the abrasion speed of the rubber lining plate and steel ball of the ball mill, which may cause equipment damage or even safety accidents in serious cases. In addition, it is also related to the ball of the ball mill. The size and quantity of the ball will affect the service life of the rubber lining plate of the ball mill. If the ball mill is in operation, increasing the amount of steel balls or filling steel balls with larger diameters will increase the wear of the rubber lining plate of the ball mill. 2. The heat treatment process of the rubber lining plate of the ball mill is unreasonable: the unreasonable heat treatment of the rubber lining plate of the ball mill will not only increase the wear of the lining plate, but also affect the yield strength of the lining plate, resulting in the fracture of the bolt of the ball mill under the large shear force. In the actual operation, the staff lacked the understanding of the lining plate material and the heat treatment processing of the ball mill rubber lining plate was insufficient, so the strengthening effect of the ball mill rubber lining plate was not in place and the strength was low. When impacted by steel balls and materials, Braided hose company Plastic deformation often occurs. 3. The material of the rubber lining plate of the ball mill is unreasonable: the material of the rubber lining plate of the ball mill and its heat treatment process are the key to determine the mechanical performance of the lining plate. If the material of the lining plate is not properly selected, its fatigue strength and life will be greatly reduced, which will not meet the requirements of the ball mill, or even plastic deformation or bulge will occur.
At present, the common air ducts in the domestic market are generally made of galvanized iron sheet, commonly known as white iron sheet. production Braided hose And the thickness is 0.44~1.22mm. The thickness of iron sheet of air duct in China is generally less than 1.5mm, and the thickness of zinc coating refers to the national standard GB/T 13912-2002: 35 μ m. Average 45 μ m。 During the production of galvanized air duct, the national standard requires us to understand the following figures: 1. Appearance: conduct appearance inspection on all hot galvanized parts, and the main surface should be smooth, free of falling off, roughness and zinc spikes (if these zinc spikes will cause damage), free of peeling, missing plating, and residual solvent residue, There shall be no zinc lump and zinc ash in the parts where hot galvanized workpieces are used or where they are corrosion resistant. Note: "Roughness" and "smoothness" are relative concepts, and the coating roughness of workpiece is different from that of mechanical roller or (and) blow molding and galvanized products (such as galvanized steel plate and galvanized steel wire). As long as the coating thickness is greater than the specified value, there may be dark or light gray uneven areas on the surface of the plated parts. White rust (mainly white or gray corrosion products of alkaline zinc oxide) is allowed on the surface of galvanized workpieces stored in wet conditions. 2. Thickness: quantitative sampling shall be carried out according to the specified test method for coating thickness test. According to the size of the main surface area of hot-dip galvanized parts, the coating thickness measured in the test shall meet the following requirements: A) For parts with the main surface area greater than 2m (i.e. large parts), the average coating thickness measured on all basic measured surfaces of each part in the sample shall not be less than the minimum value of the corresponding average coating thickness: B) For parts with the main surface area less than 2m, Braided hose company The local coating thickness measured on each basic measuring surface shall not be less than the minimum local thickness, and the average coating thickness measured on all basic measuring surfaces of the sample shall not be less than the corresponding minimum average thickness.