Jiaxing Acetylene tape It is widely used in mining, chemical industry, construction and iron and steel fields. At present, 90% of ball mills, rod mills and moistening mills on the market still use manganese steel cylinder liners, and the manganese steel material consumed on liners alone every year is more than one million tons. The emergence of rubber liners is favored by many big customers in the ball mill field. What are the indexes that affect the rubber lining plate of the ball mill? 1. Conditions of ball mill use scenario The feeding particle size of ore also plays an important role, so a good ball mill rubber lining plate will be designed according to the size of the customer's mill, feeding particle size, and steel ball diameter. Select the rubber formula suitable for customers, and carry out mapping, design, testing and processing. 2. Rubber formula and processing technology: The rubber material and formula directly affect the performance of the rubber lining plate of the ball mill. Wear resistance is a key factor. It is impossible to determine how long its service life is because of the impact of industrial and mining conditions. The second is corrosion resistance. This is the characteristic of the formula, so even if the appearance is the same, the performance is an advantage. Do not buy for cheap. 3. Regular maintenance: everyone knows that the rubber lining plate of the ball mill is fixed to the cylinder by means of T-bolts, so it is also very important to regularly check the tightness of the bolts and the wear of the rubber strips inside the cylinder. In order to avoid damaging the rubber lining plate of the cylinder and the cylinder of the ball mill when the lifting strip is worn out, the gain is not worth the loss. Acetylene tape Where can I find it? One of the advantages of the manganese steel lining plate is that the replacement is simple and only needs two people to operate, and it can be replaced wherever it is broken. This is an advantage that the manganese steel lining plate does not have.
Before construction, the technicians must be familiar with the drawings and relevant data carefully, and understand the technological process, working medium, pressure, temperature and other technical parameters as well as the materials, models and specifications of the materials and accessories used. The construction personnel must be fully familiar with the construction procedures, construction methods, quality standards, operating procedures and safety technical requirements, and strictly implement them during construction. Main materials used for making galvanized air duct, Jiaxing Acetylene tape It shall comply with the current national product standards and the enterprise standards of the manufacturer, and shall have the factory certificate and other relevant material certificates. All material accessories must be rechecked with the design and current national product standards, and shall have the factory certificate, material quality assurance and other relevant material certificates. Combined flange air duct is also called thin-walled steel plate flange air duct. It is an air duct connected by non profile steel and made of galvanized steel plate. Its connection form can be directly pressed by strips or steel plates or the air duct and flange can be integrally formed. This kind of air duct has advanced manufacturing technology, accurate blanking, low material consumption, stable product quality, many varieties, smooth contour lines, and air leakage rate far lower than the national standard, which is conducive to the production of ventilation ducts to be industrialized, large-scale, standardized and automated. It is a scientific and technological achievement project that has been vigorously promoted in China in recent years as one of the non blue air duct processes. The National Grand Theater project is to use this new process air duct. Common plate flange air duct 1 Fabrication of composite flange air duct Common mechanical equipment for fabrication of composite flange air duct include: rectangular air duct full-automatic production line, plasma automatic cutting machine, flange strip forming machine, hook code forming machine, conjoined flange forming machine, etc. The combined flange air duct is based on the air duct size given in the drawing, Acetylene tape Where can I find it? Fully automatic production line is used to produce coiled material with a common width of 1250mm, and the plate thickness is 0.5~1.2mm. When the large side of the air duct is less than or equal to 2m, the air duct is formed into TDC1 flange, and the standard pipe length is 1170mm; When the large side of the fabricated air duct is less than or equal to 2.5m, the air duct is formed into TDC2 flange, and the standard pipe length is 1250mm; When the large side of the fabricated air duct is more than 2.5m, the air duct is formed into an angle steel flange, and the standard pipe length is 1230mm
People buy in daily life wear-resisting Acetylene tape Take it home for installation. It is obviously installed very well, but the spiral air duct will become loose for a long time, which gives most users a headache. So what is the problem with spiral air duct reinforcement? This is of course necessary. The following manufacturer of galvanized spiral air duct will give you a detailed introduction. 1. Reinforcement measures shall be taken for circular pipes (excluding spiral pipes) with a diameter greater than or equal to 80 mm, a section length greater than 1250 mm or a total area greater than 4 ㎡; 2. The side length of rectangular air duct is more than 630 mm, the length of pipeline insulation side is more than 800 mm, the section length is more than 1250 mm, or the plane area of one side of low pressure pipeline is more than 1.2 m2, and that of medium and high pressure pipeline is more than 1.0 m2, so reinforcement measures should be taken; 3. For reinforcement of irregular oval pipes, the reinforcement method of rectangular pipes shall be referred to. The spiral air duct manufacturer Hongyuansheng Electromechanical also has something to say: the reinforcement of galvanized air duct non-metallic air duct should also meet the following requirements: when the diameter or side length of the rigid PVC pipe is greater than 500 mm, the connection between the pipe and the flange should be equipped with stiffening plates, and the spacing should not be greater than 450 mm. The reinforcement of organic and inorganic FRP pipes shall be made of the same materials with the same anti-corrosion performance as the pipes themselves. Acetylene tape Where can I find it? The manufacture of rectangular pipe elbows shall generally adopt concentric arc elbows with the curvature radius of the length inside and outside the plane. When other forms of elbow are used, and the plane length is more than 500 mm, the elbow deflector shall be set.
Jiaxing Acetylene tape With the continuous updating of technology, the products are also developing in the continuous updating. At present, the inspection requirements of rubber hose are also improved compared with the previous ones. The inspection index of ultra-high pressure hose shall meet the following index requirements according to the requirements of the Safety Code for High Pressure Water Jet Cleaning Operation: 1) The bursting pressure shall be more than 2.5 times of the working pressure. 2) The test pressure shall be 1.5 times of the working pressure, and the pressure shall be kept for more than 2 minutes without damage. 3) Pulse pressure shall be within the range from zero to working pressure, and 50000 pressure pulses shall be free of damage; The pulse frequency is 15 times/min when the working pressure is 1000-2800bar, and 110 times/min when the pressure is above 2800bar. Since high-pressure cleaning machine has been widely used in all walks of life, and the working condition of high-pressure hose is relatively the worst, we must pay attention to the quality when selecting high-pressure hose, so as to avoid unnecessary safety accidents. Acetylene tape Where can I find it? The development of rubber hose can not be separated from cooperation, R&D and innovation can not be separated from communication, and the inspection requirements of rubber hose have been improved compared with the previous ones. The storage site shall be free of ozone, heat source and equipment generating electromagnetic field. The coiled hoses or hose assemblies shall be stored horizontally, and the stacking height shall be limited to the extent that the products at the bottom will not produce permanent deformation.
Jiaxing Acetylene tape Compared with rectangular duct, it is widely used in the ventilation industry. Why? Let's start with its advantages to solve this problem and make it clear. At the same time, through the following introduction, I hope you can know more about the spiral duct and make yourself more professional in this regard. Now let's understand the function of air duct: function 1: air supply and ventilation. It is used to transport fresh air and waste gas, exhaust harmful gas, and deliver outdoor fresh air to the room. Generally speaking, spiral air duct is good. If the environment is humid or corrosive, stainless steel shall be used to avoid rust and corrosion of air duct. Function 2: provide cold air. It is mainly used for central air conditioning, but thermal insulation materials need to be added on the air duct. Function 3: Exhaust lampblack: It is mainly used to exhaust kitchen lampblack in restaurants, hotels and other places. Generally, circular air ducts are used. Function 4: dedusting and bulk material conveying: in the factory workshop, the air duct is used for dedusting, and the spiral air duct can be used for conveying particles, such as foam plastic particles, because Acetylene tape Where can I find it? The proportion of products is small. 1) Under the same plate thickness and pipe diameter, the strength of spiral air duct is higher. (2) Under the same section, the structural tension of spiral air duct is more reasonable, the stiffness is better, and the noise and vibration can be greatly reduced. (3) At the same length, the number of flange connections of spiral air duct is less, which can greatly improve the ventilation quality of the system.