Changsha Braided hose Main impact: The air volume loss of the whole system is too large to meet the air volume requirements, and the power is seriously wasted. 1. If the stainless steel welded air duct system adopts the combined flange air duct, it may be that the seam, flange strip seam and hole seam are not sealed with sealant; The allowance of segment blanking seaming is greater than the specification requirements. 2. No embedded parts are set at the joint of brick structure air duct and metal air duct, or the sealing gap is too large or the joint is not tight. Countermeasures: 1. Button type seaming can be used for medium pressure air duct; Corner seam or joint corner seam shall be used at four corners of high-pressure air duct or clean system air duct. 2. Seams of stainless steel welded air ducts, joints without flange inserts and holes must be sealed with sealing paste to prevent air leakage. 3. During construction, embedded parts shall be set at the junction of brick, structural air duct and metal air duct as required, or the civil engineering unit shall cooperate to block and seal to ensure close connection. During the air duct anti-corrosion treatment, the next anti-corrosion treatment can be carried out after the previous paint is dried; It is strictly forbidden to work without certificate. The duct type air outlet is a central air conditioning terminal air supply system that integrates the functions of air outlet, air supply pipeline, static pressure box, thermal insulation material, air valve, etc. Braided hose company Calculation of air duct size of stainless steel welded air duct: the equal damping method (equal pressure method) is a convenient calculation method, which is suitable for many occasions.
“ high quality Braided hose What are the applications in engineering transformation? " In this issue, we will explain this problem for you. Those who have consulted this problem will come to see it: First, we should consider the water supply and drainage of all water related equipment, such as wells, pumps, etc., their location, installation method and temperature, including galvanized air ducts. 2、 It is very important to consider galvanized air duct in advance to avoid temporary replacement of galvanized air duct materials. 3、 After the location of the machine tool is determined, the drainage outlet can be considered to be arranged underground, which is not only convenient but also durable. 4、 After river reconstruction, there should be a suppression test, but now many construction teams do not suppress the test. It is usually said that it is not important, that there is water and pressure in the galvanized air duct, and so on. Try to be present to suppress the test. 5. If the installation is completed, pay attention to the inspection of the workshop, water pump room and FRPP drain. If the drainage system is slow, the installation program should be able to open the installation. Water outlets should be protected, especially during civil engineering construction, Braided hose company It may cause soil loss and blockage. I believe that you have a better understanding of this information, and we will continue to improve the galvanized air duct to make it more widely used.
high quality Braided hose The manufacturing of is highly automated and the production speed is very fast. The general air duct can produce 20~40 meters per minute. Due to the low price of its raw material galvanized strip steel compared with the whole galvanized steel sheet, and its factory production and specification standardization, the cost of spiral air duct is lower than that of rectangular air duct; In addition, the total cost of spiral air duct is low due to the less demand for supports and hangers and the less installation work. Since the four corners of rectangular air ducts are prone to turbulence, reducing the effective flow area, the spiral air ducts have good air fluidity and large effective flow area, so the secondary noise of spiral air ducts is low. Because the spiral air ducts are strong, the low-frequency noise caused by air duct vibration is smaller, the air flow performance is good, the system pressure drop is small, and the daily operation system consumes less power. Spiral air ducts in the market are generally divided into three categories according to their materials: galvanized spiral air ducts, stainless steel spiral air ducts and composite spiral air ducts. Among them, spiral air duct has the best quality and strong applicability, but its price is high. At present, the most widely circulated spiral air duct on the market is galvanized sheet. The galvanized sheet spiral air duct is basically the characteristic of stainless steel spiral air duct, but its price is only two thirds or even lower than that of spiral air duct. Changsha Braided hose It is generally used in places where the external environment is relatively common and the requirements for air ducts are not too high. As the iron sheet is prone to chemical reaction in various environments, corrosion and rust will occur. However, zinc hardly changes in dry air. In humid air, dense basic zinc carbonate film will be formed on the surface of zinc. The spiral air duct is mainly coated with zinc on the iron sheet of the air duct to protect the iron sheet. The protective and decorative properties of zinc coating can be significantly improved after passivation treatment, dyeing or coating with light protecting agent.
Air duct mainly refers to the ventilation duct of the central air-conditioning system, which is often ignored, but it is an important part of the air-conditioning system. Changsha Braided hose What are the regulations for welding air ducts? Gongfa HVAC is a manufacturer dedicated to the production of air ducts, which has been recognized and supported by the majority of users for many years. 1、 The welding regulations of carbon steel plate air duct are as follows: 1. The carbon steel plate air duct should be welded by DC welder. Introduction to welding air duct If AC welding machine is used for welding, a vibrator must be added to reduce excitation and stabilize the arc. When welding steel plates, the arc is unstable, which can lead to deterioration of weld quality. 2. Before welding, remove the dirt, oil stain and rust at the welding port; When spot welding or continuous welding is used, the oxide shall also be removed. The butt joint shall be kept with the minimum gap, and the overlap at the manual spot welding location shall be removed in time. After welding, the electrode slag and residual welding wire in the weld and its surrounding area shall be removed in time. 2、 The welding regulations of stainless steel air duct are as follows: 1. Before welding the air duct, remove the grease and dirt in the weld area to prevent pores and sand holes in the weld. Cleaning can be carried out with gasoline, acetone, etc. When welding stainless steel plates by electric arc welding, the surfaces on both sides of the weld should be coated with white ash, Changsha Braided hose To avoid welding slag splashes adhering to the surface of the plate. 2. After welding, attention shall be paid to removing the slag at the weld, brushing the metal luster with a copper wire brush, pickling with 10% nitric acid solution, and then cleaning with hot water.