At present, the common air ducts in the domestic market are generally made of galvanized iron sheet, commonly known as white iron sheet. wear-resisting Sanding pipe And the thickness is 0.44~1.22mm. The thickness of iron sheet of air duct in China is generally less than 1.5mm, and the thickness of zinc coating refers to the national standard GB/T 13912-2002: 35 μ m. Average 45 μ m。 During the production of galvanized air duct, the national standard requires us to understand the following figures: 1. Appearance: conduct appearance inspection on all hot galvanized parts, and the main surface should be smooth, free of falling off, roughness and zinc spikes (if these zinc spikes will cause damage), free of peeling, missing plating, and residual solvent residue, There shall be no zinc lump and zinc ash in the parts where hot galvanized workpieces are used or where they are corrosion resistant. Note: "Roughness" and "smoothness" are relative concepts, and the coating roughness of workpiece is different from that of mechanical roller or (and) blow molding and galvanized products (such as galvanized steel plate and galvanized steel wire). As long as the coating thickness is greater than the specified value, there may be dark or light gray uneven areas on the surface of the plated parts. White rust (mainly white or gray corrosion products of alkaline zinc oxide) is allowed on the surface of galvanized workpieces stored in wet conditions. 2. Thickness: quantitative sampling shall be carried out according to the specified test method for coating thickness test. According to the size of the main surface area of hot-dip galvanized parts, the coating thickness measured in the test shall meet the following requirements: A) For parts with the main surface area greater than 2m (i.e. large parts), the average coating thickness measured on all basic measured surfaces of each part in the sample shall not be less than the minimum value of the corresponding average coating thickness: B) For parts with the main surface area less than 2m, Sanding pipe company The local coating thickness measured on each basic measuring surface shall not be less than the minimum local thickness, and the average coating thickness measured on all basic measuring surfaces of the sample shall not be less than the corresponding minimum average thickness.
Baoji Sanding pipe Air conditioning and ventilation engineering equipment applicable to industry and various buildings, widely used in food processing, machinery production, pharmaceutical products, electronic industry, cotton textile, sports entertainment and cultural places, hotels, hotels, office buildings, small villas, etc. Stainless steel air ducts are widely used in air conditioning and ventilation systems. The product covers almost all industries and has a very high penetration rate. After years of continuous development, this technology has achieved a qualitative leap in the industry. The overall structure of stainless steel welded air duct products is combined, which can flexibly form any direction. Each part of the chimney is basically assembled into a separate part by the inner pipe, outer pipe, ring plate, support, insulation materials, etc. The connection between sections shall be sealed with special materials and accurately combined with the hoop. The corner and steering parts are clamped by elbows, tees, etc. The displacement caused by temperature difference is fully compensated by expansion joints and compensators. The explosion-proof door is installed at the boiler outlet or local horizontal flue. When multiple boilers share a chimney, the steering valve plate can be used for effective control. Stainless steel welded air duct is very common in our life. According to different uses, shapes and processing technologies, pipes can be divided into several types. Depending on the use and location, Sanding pipe company It can be divided into purification system air supply, industrial air supply and exhaust, environmental protection system air supply and exhaust, air conditioning and ventilation, etc. For process workers, it is divided into angle iron air duct and flange air duct. With the continuous development of economy, the use range of ventilation equipment is also expanding, and the role of equipment cannot be ignored. With the progress of science and technology, the technical level of all walks of life is also constantly improving. Ventilation equipment is no exception, and the equipment is becoming more and more perfect.
You know? Baoji Sanding pipe Are there reinforcement regulations and requirements? Stainless steel welded air duct is a commonly used equipment, and its reinforcement actually has regulations and requirements, do you know? If in pipe support is adopted, the spacing between each support point and the edge or flange of the air duct shall be uniform, and the value shall not be greater than 950 mm. If the corrugated bars or wires are used for reinforcement, the arrangement should be regular and the spacing should be even. Moreover, there should be no obvious deformation and other problems for the board surface. If the welded air duct is reinforced, it should be made of ribbed bars, vertical bars, angle steel, flat steel, reinforcing bars and supports inside the duct. The appropriate one can be selected according to the actual situation and needs. If angle steel or reinforcing bars are used, they should also be arranged neatly and symmetrically. The height shall not be greater than the flange width. Principles and requirements for stainless steel air duct plate connection. When the thickness is less than or equal to 1mm, the splicing of plates shall be done by biting or riveting. When the thickness of plates is greater than 1mm, argon arc welding or electric arc welding shall be used instead of gas welding. The mature argon arc welding process of "single side welding, double side forming" shall be adopted; When assembling weldments, the welding materials and process measures selected for spot welding shall be consistent with the formal Sanding pipe company The requirements are the same. The misalignment deviation of the pipe butt joint is less than 20% of the wall thickness and less than 2mm. Adjust the butt joint clearance, and do not use the method of heating, tensioning and twisting the pipe. It is not allowed to strike an arc or test the current on the weldment, and the pipe surface shall be free of arc scratch and other defects. Splash prevention measures shall be taken during welding. After welding, the slag and spatter shall be cleaned with stainless steel flat shovel. After welding, the slag on the weld surface and the spatter on both sides shall be cleaned.
How to install correctly Baoji Sanding pipe ? In the fire smoke exhaust pipe system, the airport and air valve must use non fuel, and the thickness of citizen flue and galvanized ventilation pipe should be improperly used. The high-pressure system should be selected according to the national code GB50243. When the fire smoke exhaust fan is installed on the roof, certain maintenance measures should be taken. The exposed power line must be threaded through the conduit, and the conduit material should be combined with the metal hose or Capelli and duck neck equipment to make it curved. The fire fighting system and equipment lines must be fixed with special clamps to avoid falling. Stainless steel air duct and ventilation equipment shall be made of three fabric flame retardant materials with soft connection. It is suggested that the length should be 15-30cm, and the electrical interpenetration should be completed. Bolts require the same length. The three main bodies should be grounded, ventilation equipment, and equipment and devices between dynamic loads should be equipped with shock absorption measures. When Sanding pipe company Box type pipe fittings should not be used for changing direction, variable diameter, branch road, or junction, but the wind speed of box section should not exceed 1.5m/s for air distribution and static pressure box when necessary; It is advisable to have 5-10 times the pipe diameter between conduit pipes. The length of expandable metal pipes or non-metallic soft links should not exceed 2 meters. There should be no disintegration and dead corners. During the installation process, when the length of pipe elbows and straight pipes exceeds 20 meters, add anti impact frame open room exhaust fans and add or subtract supports.